Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/28/19

Message Overview:

Fault Message:

DCPC FT SUPERVISOR CARD-A13 FAILED

Fault Code:

2460413DCP

Associated CAS:

ELEC SYS FAIL
(Caution)

Reporting LRU: DC Power Center (DCPC)
System Description: 24-60-00
Schematic Diagram: 24-61-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 24-61-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

DC Power Center (DCPC) Fault Tolerant Supervisor Card has an internal fault.

Possible Causes:

  • Fault Tolerant Supervisor Card (A13)
  • DC Power Center (DCPC) (A63)

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the DC Power Center (DCPC) AMM 24-61-00-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the DC Power Center (DCPC) AMM 24-61-00-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the DC Power Center (DCPC) Fault-Tolerant Supervisor AMM 24-61-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the DC Power Center (DCPC) Fault-Tolerant Supervisor AMM 24-61-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
DC Power Center (DCPC) Assembly CMM 24-61-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Remove power from the A/C. After 15 seconds, apply power to the A/C. Is the fault still present?

    1. If NO, do close out.
    2. If YES, continue with next step.

  2. Access the DCPC Logic assembly. Remove the Supervisor card. Carefully inspect all the contacts on the card and the mating connector contacts inside the DCPC.

    1. If any damage is found on the DCPC motherboard, replace DCPC and do close out.
    2. If any damage is found on the card, continue with next step.
    3. If no damage is found, continue with next step.

  3. Replace the Supervisor card.
  4. Do close out.