06/28/19
Message Overview:
Fault Message:
DCPC TLC1-TTC1 CONTACTOR-K1 FAILED
Fault Code:
2460423DCP
Associated CAS:
| Reporting LRU: | DC Power Center (DCPC) |
| System Description: | 24-60-00 |
| Schematic Diagram: | 24-61-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-61-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Primary Logic Cards (PLC) detects a discrepancy between coil drive status and auxiliary contact status.
Possible Causes:
- DC Power Center (DCPC) Contactor K1
- DC Power Center (A63)
- Primary Logic Card (PLC) 1
- Primary Logic Card (PLC) 2
- Primary Logic Card (PLC) 3
- Electromagnetic Interference (EMI) Filter
- Electromagnetic Interference 1 (EM 1)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the DC Power Center (DCPC) | AMM 24-61-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) | AMM 24-61-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC) Primary Logic | AMM 24-61-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) Primary Logic | AMM 24-61-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC)L-Series Contactor | AMM 24-61-53-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC)L-Series Contactor | AMM 24-61-53-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC) Electronic Modules | AMM 24-61-65-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) Electronic Modules | AMM 24-61-65-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- On the DC synoptic page, make sure TRU1 icon is green and is supplying 28 VDC.
- Get access to the DCPC contactor K1.
- Disconnect contactor K1 connector P104.
- In the cockpit, turn the BATT MSTR SW to ON.
- Perform a voltage check for 28 VDC as follows:
From To Result P104-1 Ground P104-2 Ground - If there is 28 VDC, go to step 8.
- If there is no 28 VDC, continue with next step.
- Disconnect EM1 connector P105. Perform a voltage check for 28 VDC as follows:
From To Result P105-23 Ground - If there is 28 VDC, go to next step.
- If there is no voltage, go to step 15.
- Perform a continuity check as follows:
From To Result P105-25 P104-1 - If there is continuity, replace EM1 and do close out.
- If there is no continuity, go to step 15.
- Perform a continuity check as follows:
From To Result P104-5 Ground P104-7 Ground - If there is continuity, continue with next step.
- If there is no continuity, go to step 15.
- Remove PLC 1, PLC 2 and PLC 3.
- Perform a continuity check as follows:
From To Result P104-6 Ground P104-8 Ground P104-22 Ground P104-3 Ground - If there is continuity, go to step 15.
- If there is no continuity, continue with next step.
- Perform a continuity check as follows:
From To Result P104-3 P110C-18 P104-6 P110A-17 P104-8 P110A-18 P104-22 P110C-17 P104-3 P210C-18 P104-6 P210A-17 P104-8 P210A-18 P104-22 P210C-17 P104-3 P310C-18 P104-6 P310A-17 P104-8 P310A-18 P104-22 P310C-17 - If there is continuity, continue with next step.
- If there is no continuity, go to step 15.
- Install PLC 2 and PLC 3. Is the fault resolved.
- If YES, replace PLC 1 and do close out.
- If NO, install PLC 1 and remove PLC 2 and continue with next step.
- Replace PLC 2. Is the fault resolved?
- If YES, do close out.
- If NO, reinstall PLC 2 and remove PLC 3.
- Replace PLC 3. Is the fault resolved?
- If YES, do close out.
- If NO, reinstall PLC 3 and go to step 16.
- Replace DCPC.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace Contactor K1.
- Do close out.