background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults By CAIMS By Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/28/19

Message Overview:

Fault Message:

DCPC SSPC1-K7 FAILED

Fault Code:

2460428DCP

Associated CAS:

ELEC SYS FAIL
(Caution)

Reporting LRU: DC Power Center (DCPC)
System Description: 24-60-00
Schematic Diagram: 24-61-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 24-61-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

When voltage is present on DC Bus 1 while DC Power Center (DCPC) Solid-State Power Controller (SSPC) 1 is off and there is voltage on the SSPC 1 output, the continuous monitoring test will fail. This will indicate SSPC 1 or Diode (D1) short circuit fault.

Possible Causes:

  • Solid-State Power Controller (SSPC) 1
  • Diode (D1)
  • DC Power Center (DCPC) (A63)
  • Primary Logic Card (PLC) 1
  • Primary Logic Card (PLC) 2
  • Primary Logic Card (PLC) 3
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the DC Power Center (DCPC) AMM 24-61-00-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the DC Power Center (DCPC) AMM 24-61-00-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the DC Power Center (DCPC) Primary Logic AMM 24-61-09-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the DC Power Center (DCPC) Primary Logic AMM 24-61-09-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the DC Power Center (DCPC) P700-Series Contactors AMM 24-61-21-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the DC Power Center (DCPC) P700-Series Contactors AMM 24-61-21-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
DCPC assembly CMM 24-61-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Get access to CAIMS active faults. Is message 2460446DCP DCPC DIODE 1 (D1) FAILED posted?

    1. If YES, troubleshoot this message first.
    2. If NO, continue with next step.

  2. Disconnect SSPC1 (K7) connector P103. Remove all three Primary Logic Cards (PLC 1, PLC 2 and PLC 3) from the DCPC. Perform a continuity check of SSPC 1 Coil status, Coil command, load status and gate status as follows:

    From To Result
    P103-3 Ground
    P103-4 Ground
    P103-6 Ground
    P103-12 Ground

    1. If there is continuity, replace DCPC and do close out.
    2. If there is no continuity, continue with next step.

  3. Perform a continuity check as follows:

    From To Result
    P103-3 P110A-7
    P103-3 P210A-7
    P103-3 P310A-7
    P103-4 P110B-18
    P103-4 P210B-18
    P103-4 P310B-18
    P103-6 P110A-13
    P103-6 P210A-13
    P103-6 P310A-13
    P103-12 P110B-17
    P103-12 P210B-17
    P103-12 P310B-17

    1. If there is no continuity, replace DCPC and do close out.
    2. If there is continuity, continue with next step.

  4. Replace SSPC 1 (K7). Is the fault resolved?

    1. If YES, do close out.
    2. If NO, continue with next step.

  5. Perform SmartFix Plus task for fault code 2460446DCP.
  6. Do close out.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.