Message Overview:
Fault Message:
ASCA FAILED (LEVEL A)
Fault Code:
2460432DCP
Associated CAS:
| Reporting LRU: | DC Power Center (DCPC) |
| System Description: | 24-60-00 |
| Schematic Diagram: | 24-61-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-61-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The DC Power Center (DCPC) Primary Logic Cards (PLCs) detect a discrepancy between the Solid State Power Controller (SSPC) 5 status and its commanded state.
Possible Causes:
- Auxiliary Power Unit (APU) Starter-Contactor Assembly (ASCA) (A48)
- DC Power Center (DCPC) (A63)
- Primary Logic Card (PLC) 1
- Primary Logic Card (PLC) 2
- Primary Logic Card (PLC) 3
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
NOTE: The troubleshooting for this particular fault code should be done with only Battery Master Switch (BMS) ON. External power ON is not required.
Quick Links:
| Removal of the DC Power Center (DCPC) | AMM 24-61-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) | AMM 24-61-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the APU Starter-Contactor Assembly | AMM 24-62-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the APU Starter-Contactor Assembly | AMM 24-62-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| DCPC assembly | CMM 24-61-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Get access to the APU Battery and disconnect connector A89P2.
- Get access to the ASCA and disconnect connector A48P2.
- Make sure circuit breaker CB-D2 is close on CCPB.
- Perform continuity check as follows:
From To Result A48P2-S Ground - If there is continuity, repair defective wiring as required and do close out.
- If there is no continuity, continue with next step.
- Remove all 3 DCPC PLCs.
- Perform continuity check as follow:
From To Result A48P2-B Ground A48P2-L Ground - If there is no continuity, go to step 10.
- If there is continuity, continue with next step.
- Get access to the DCPC and disconnect connector A63P1.
- Perform wiring checks (shorted to ground=failure) as follow:
From To Result A48P2- Ground A48P2-L Ground - If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace the ASCA. Is the fault still present?
- If YES, continue with next step.
- If NO, do close out.
- Replace DCPC.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Do close out.