Message Overview:
Fault Message:
DCPC TRU 1 CURRENT XDCR-IS5 FAILED
Fault Code:
2460465DCP
Associated CAS:
| Reporting LRU: | DC Power Quality Monitor (DCPQM) |
| System Description: | 24-31-00 |
| Schematic Diagram: | 24-31-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-31-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The DC Power Quality Monitor (DCPQM) has detected a Transformer Rectifier Unit (TRU) 1 over current while other TRUs are available and K1 is open and not failed.
The DCPQM has detected a TRU 1 current near zero while no other TRU power is available and K1 is ON.
Possible Causes:
- DC Power Center (DCPC) Current Transducer (IS5)
- DC Power Quality Monitor (DCPQM) 1
- DC Power Center (DCPC) (A63)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the DC Power Center (DCPC) | AMM 24-61-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) | AMM 24-61-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC) DC Power Quality Monitor | AMM 24-61-13-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) DC Power Quality Monitor | AMM 24-61-13-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC) Current Transducers | AMM 24-61-29-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) Current Transducers | AMM 24-61-29-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Access CAIMS active faults. Is message 2460423DCP DCPC TLC1- TTC1 CONTACTOR-K1 FAILED posted?
- If YES, troubleshoot this message first.
- If NO, continue with next step.
- Access DCPC logic assembly. Swap DCPQM 1 with DCPQM 2. Is the fault resolved?
- If YES, replace DCPQM 1 and do close out.
- If NO, continue with next step.
- Replace current transducer IS5. Is the fault resolved?
- If YES, do close out.
- If NO, continue with next step.
- Replace DCPC.
- Do close out.