06/28/19
Message Overview:
Fault Message:
DCPC ESS TRU2 CURRENT XDCR-IS3 FAIL
Fault Code:
2460475DCP
Associated CAS:
| Reporting LRU: | DC Power Quality Monitor (DCPQM) |
| System Description: | 24-31-00 |
| Schematic Diagram: | 24-31-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-31-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The DC Power Quality Monitor (DCPQM) has detected an Essential Transformer Rectifier Unit (ESS TRU) 2 over current while other TRUs are available and K3 is open and not failed.
The DCPQM has detected an ESS TRU 2 current near zero while no other TRU power is available and K3 is on.
Possible Causes:
- Current Transducer (IS3)
- DC Power Quality Monitor (DCPQM) 2
- DC Power Center (DCPC) (A63)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the DC Power Center (DCPC) | AMM 24-61-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) | AMM 24-61-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC) DC Power Quality Monitor | AMM 24-61-13-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) DC Power Quality Monitor | AMM 24-61-13-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC) Current Transducers | AMM 24-61-29-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) Current Transducers | AMM 24-61-29-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Access CAIMS active faults. Is message 2460425DCP DCPC TLC3-TTC3 CONTACTOR-K3 FAILED posted?
- If YES, troubleshoot this message first.
- If NO, continue with next step.
- Access DCPC logic assembly. Swap DCPQM 2 with DCPQM 1. Is the fault resolved?
- If YES, replace DCPQM 2 and do close out.
- If NO, continue with next step.
- Replace current transducer IS3. Is the fault resolved?
- If YES, do close out.
- If NO, continue with next step.
- Replace DCPC.
- Do close out.