Message Overview:
Fault Message:
RAT GCU FAILED
Fault Code:
2460490DCP
Associated CAS:
| Reporting LRU: | DC Power Center (DCPC) |
| System Description: | 24-23-00 |
| Schematic Diagram: | 24-23-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-23-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
DC Power Center (DCPC) detected a Ram-Air-Turbine Generator Control Unit (RAT GCU) internal failure.
Possible Causes:
- Ram-Air-Turbine Generator Control Unit (RAT GCU) (A191)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700T-0055 - DC BUS 2 shedding while performing 24 months Operational Test of the Ram Air Turbine (RAT)
- AW700T -0110 Rev2 - Incorrect Installation of Ram Air Turbine - Generator Control Unit Connector EMI Filters
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Operational Test of the Ram Air Turbine (RAT) | AMM 24-23-01-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Ram-Air-Turbine Generator Control Unit (RAT GCU) | AMM 24-23-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Ram-Air-Turbine Generator Control Unit (RAT GCU) | AMM 24-23-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Perform ground check portion of AMM 24-23-01-710-01 ops test of RAT.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace RAT GCU.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Perform wiring checks between RAT GCU, RAT GEN, DCPC, and SPDA 1.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace DCPC.
- Do close out.