06/28/19
Message Overview:
Fault Message:
DCPC BATT BUS FAILED
Fault Code:
2460505DCP
Associated CAS:
| Reporting LRU: | DC Power Center (DCPC) |
| System Description: | 24-60-00 |
| Schematic Diagram: | 24-61-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-61-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Two conditions:
- BATT BUS is not powered.
- BATT BUS is isolated by the Primary Logic Cards (PLCs) due to BUS fault detection.
Possible Causes:
- Contactor (K3)
- Contactor (K5)
- Electronic Module (EM4)
- Secondary-Power Distribution (SPDA) Feeder Assembly BATT BUS Card
- DC Power Center (DCPC) (A63)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
NOTE: A K5 (ETC) failure will only show itself when at least one TRU is failed.
Quick Links:
| Removal of the DC Power Center (DCPC) | AMM 24-61-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) | AMM 24-61-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC) Secondary-Power Distribution Assembly (SPDA) Feeder |
AMM 24-61-37-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) Secondary-Power Distribution Assembly (SPDA) Feeder |
AMM 24-61-37-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC) L-Series Contactor | AMM 24-61-53-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) L-Series Contactor | AMM 24-61-53-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC) Electronic Modules | AMM 24-61-65-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) Electronic Modules | AMM 24-61-65-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Does this failure only occur when a TRU is failed or off?
- If NO, go to step 3.
- If YES, continue with next step.
- Access DCPC contactor assembly. Perform a voltage check for 28 VDC as follows:
From To Result K5-B1 Ground K5-B2 Ground - If there is no 28 VDC, replace K5 and do close out.
- If there is 28 VDC, go to step 5.
- Access DCPC contactor assembly. Power on the A/C and make sure ESS TRU 2 is powered. Perform a voltage check for 28 VDC as follows:
From To Result K3-A1 Ground - If there is no 28 VDC, troubleshoot the wiring between ESS TRU 2 and the DCPC and do close out.
- If there is 28 VDC, continue with next step.
- Remove electrical power from the aircraft. Perform a voltage check for 28 VDC as follows:
From To Result K3-A2 Ground - If there is no 28 VDC, replace K3 and do close out.
- If there is voltage, continue with next step.
- Disconnect EM4 connector P407. Perform a continuity check as follows:
From To Result P407-12 Ground P407-15 Ground - If there is continuity, go to step 11.
- If there is no continuity, continue with next step.
- Perform a continuity check as follows:
From To Result P407-12 K3-A2 P407-15 K3-A2 - If there is no continuity, go to step 11.
- If there is continuity, continue with next step.
- Remove the BATT SPDA FEEDER CARD. Perform a continuity check as follows:
From To Result P407-13 Ground P407-16 Ground P407-11 Ground - If there is continuity, go to step 11.
- If there is no continuity, continue with next step.
- Perform a continuity check as follows:
From To Result P431A-8 P407-13 P431A-9 P407-16 P431A-10 P407-11 - If there is no continuity, go to step 11.
- If there is continuity, continue with next step.
- Swap the BATT SPDA FEEDER with DC BUS 2 SPDA FEEDER Card. Does the fault follow the card?
- If YES, replace BATT SPDA FEEDER and do close out.
- If NO, continue with next step.
- Replace EM4.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace DCPC.
- Do close out.