Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/28/19

Message Overview:

Fault Message:

DCPC DC EMER BUS FAILED

Fault Code:

2460506DCP

Associated CAS:

ELEC SYS FAIL
(Caution)

Reporting LRU: DC Power Center (DCPC)
System Description: 24-60-00
Schematic Diagram: 24-61-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 24-61-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

  1. DC EMER BUS is not powered.
  2. DC EMER BUS is isolated by the Primary Logic Cards (PLCs) due to BUS fault detection.

Possible Causes:

  • Battery Bus (BATT BUS)
  • Diode (D6)
  • Circuit Breaker (CBC4)
  • Circuit Breaker (CBC6)
  • Contactor (K6)
  • Battery/Ram-Air-Turbine Interface (BATT/RAT IF) Card
  • DC Power Center (DCPC) (A63)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None: None

Forum Articles/Infoservice/Newsletter: None

NOTE:

  • Make sure that the DCPC Circuit Breakers (CBC4 and CBC6) are not tripped, physically
  • Make sure that Avionics Battery direct BUS is powered

Quick Links:

Removal of the DC Power Center (DCPC) AMM 24-61-00-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the DC Power Center (DCPC) AMM 24-61-00-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the DC Power Center (DCPC) Primary Logic AMM 24-61-09-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the DC Power Center (DCPC) Primary Logic AMM 24-61-09-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the DC Power Center (DCPC) Battery/Ram-Air-Turbine
Interface Unit
AMM 24-61-33-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the DC Power Center (DCPC) Battery/Ram-Air-Turbine
Interface Unit
AMM 24-61-33-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the DC Power Center (DCPC) Circuit Breakers AMM 24-61-45-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the DC Power Center (DCPC) Circuit Breakers AMM 24-61-45-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Get access to CAIMS active faults, check for the following fault messages, troubleshoot them one by one if they are posted:
  2. Access DCPC contactor assembly. Perform a voltage check for 28 VDC as follows:

    From To Result
    CBC4 contact 2 Ground

    1. If there is no 28 VDC, replace CBC4 and do close out.
    2. If there is 28 VDC, continue with next step.

  3. Perform a voltage check for 28 VDC as follows:

    From To Result
    CBC6 contact 2 Ground

    1. If there is no 28 VDC, replace CBC6 and do close out.
    2. If there is voltage, continue with next step.

  4. Access DCPC contactor assembly. Perform a voltage check for 28 VDC as follows:

    From To Result
    K3-A2 Ground

    1. If there is no 28 VDC, replace K3 and do close out.
    2. If there is 28 VDC, continue with next step.

  5. Remove PLC 1, PLC 2 and PLC 3. Perform a continuity check as follows:

    From To Result
    P110B-8 Ground
    P210B-8 Ground
    P310B-8 Ground

    1. If there is continuity, go to step 8.
    2. If there is no continuity, continue with next step.

  6. Perform a continuity check as follows:

    From To Result
    P110B-35 K6-B2
    P210B-35 K6-B2
    P310B-35 K6-B2

    1. If there is continuity, go to step 8.
    2. If there is no continuity, continue with next step.

  7. Remove BATT/RAT I/F card. Perform a continuity check as follows:

    From To Result
    P410B-25 Ground
    P410B-27 Ground

    1. If there is no continuity, continue with next step.
    2. If there is continuity, replace BATT/RAT IF card and do close out.

  8. Replace DCPC.
  9. Do close out.