Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

04/25/25

Message Overview:

Message Name:

RAT GEN HEATER FAILED

Message Code:

2460507DCP

Associated CAS:

ELEC SYS FAIL
(Caution)

Reporting LRU: Secondary-Power Distribution Assembly (SPDA) 1
System Description: 24-23-00 Emergency AC Power Supply
Schematic Diagram: 24-23-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: [ Global Express ]  [ G5000 ]  [ Global XRS ] - 24-32-01 Sheet 1 - Emergency AC Power Generation System - 9002, 9004-9109
Global Express ]  [ G5000 ]  [ Global XRS ] - 24-32-01 Sheet 2 - Emergency AC Power Generation System - 9003, 9110-9158
[ Global Express ]  [ G5000 ]  [ Global XRS ] - 24-32-01 Sheet 1 - ALL

Message Description:

  • DC Power Center (DCPC) Battery Ram-Air Turbine (BATT/RAT) Card has not received the Istatus flag from Secondary-Power Distribution Assembly (SPDA) 1 Ram Air Turbine Generator (RAT GEN) Heater Solid-State Power Controller (SSPC)
  • The Istatus Flag is set when the RAT GEN Heater load current is greater than 20% of the SSPCs rating

Possible Causes:

  • Ram Air Turbine Generator (RAT GEN) Heater
  • Secondary-Power Distribution Assembly (SPDA) 1 (A13)
  • DC Power Center (DCPC) Battery Ram Air Turbine (BATT/RATT) Card
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Full Throttle Blog/Forum Articles/Infoservice/Newsletter: None

Flight Operation Notifications Manual (FONM): None

NOTES:

  • The RAT GEN TEST on EMS CDU can be performed twice to try to reset the FAIL messages. If EICAS are still posted, those messages should not be considered as nuisance.
  • The RAT GEN HEATER FAIL CAIMS message can be dispatched per MMEL (refer to applicable MMEL) as long as the ELEC SYS FAIL Amber CAS message has been confirmed to be triggered by the RAT GEN heater only.
  • Fault confirmation procedure:
    Get access to EMS CDU signboard menu:

On EMS CDU 1(2), select Diagnostic mode (also referred as Extended Functions)

  1. Select SYSTEM - CNTL key (page 1)
  2. Select lower Left line select key
  3. Select lower Right line select key
  4. Select Circuit Breaker - STAT key
  5. Select DAU OUT
  6. Select and record label 271
  7. Make sure that only bit 18 is at '1'
Left Column Center Column
29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14
271 ELEC SYS FAIL (Level A) x x x x x x x x

Label 271 Bit 18 = 1 (DCPC):

  1. On EMS CDU 1, select CIRCUIT BREAKER - STATUS key
  2. Select SYSTEM - CNTL key (page 1)

    • Select lower left key
    • Select lower right key

  3. On EMS CDU 1, select Signboard DCPC IN.
  4. On EMS CDU 1, select and record labels 353 to 364.
  5. Make sure that only label 364 bit 28 is set to "1" (RAT GEN HEATER FAIL)

    1. If YES, the aircraft can be dispatched per MMEL (Refer to applicable MMEL).
    2. If NO, other failure(s) must be fixed prior to dispatch.

Left Column Center Column
29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14
Label 353
Label 354
Label 355
Label 356
Label 357
Label 358
Label 359
Label 360
Label 361
Label 362
Label 363
Label 364

Quick Links:

Standard Aircraft Configuration for Maintenance [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM12-00-00-867-801
Connect Electrical Power to the Aircraft [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM24-00-00-861-801
Electrical/Electronic Safety Precautions [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM24-00-00-910-801
Electrostatic Discharge Safety Precautions [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM24-00-00-910-802
Manual Extension of the Ram Air Turbine (RAT) [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM24-23-01-840-801
Retraction of the Ram Air Turbine (RAT) After Manual and Automatic Extension [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM24-23-01-840-803
Operational Test of the Ram Air Turbine (RAT) [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM24-23-01-710-801
Removal of the Ram-Air-Turbine (RAT) Heater [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM24-23-33-000-801
Installation of the Ram-Air-Turbine (RAT) Heater [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM24-23-33-400-801
Removal of the Secondary-Power Distribution Assemblies [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM24-62-01-000-801
Installation of the Secondary-Power Distribution Assemblies [ G5000 ]  [ Global Express ]  [ Global XRS ] AMM24-62-01-400-801

Troubleshooting Recommendations:

  1. Check resistance of RAT Heater coil as follows:

    From To Result
    G1P3-A G1P3-B

    1. If open circuit or resistance is outside of 5.9 ± 0.3 ohms, go to step 4.
    2. If resistance is within range, continue with next step.

  2. Perform wiring checks between RAT Heater and SPDA 1.

    1. If wiring checks are not good, repair defective wiring as required and do close out.
    2. If wiring checks are good, continue with next step.

  3. Interchange SPDA 1 with SPDA 2, 3 or 4. Is the fault still present?

    1. If NO, replace SPDA 1 and do close out.
    2. If YES, continue with next step.

  4. Replace RAT Heater.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  5. Replace DCPC BATT/RAT Card.
  6. Do close out.