07/01/19
Message Overview:
Fault Message:
SPDA 2 FAILED (LEVEL A)
Fault Code:
2462623SPD
Associated CAS:
| Reporting LRU: | Secondary Power Distribution Assembly (SPDA) 2 |
| System Description: | 24-60-00 |
| Schematic Diagram: | 24-62-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-62-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Secondary Power Distribution Assembly (SPDA) 2 has detected an internal failure related to the Supervisor Card (incorrect Microprocessors data exchange, Microprocessor swap test not performed successfully or address/databus is corrupted) and/or the DC Power Module Card.
Possible Causes:
- Secondary Power Distribution Assembly (SPDA) 2 (A14)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Connect Electrical Power to the Aircraft | AMM 24-00-00-861-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Remove the Electrical Power from the Aircraft | AMM 24-00-00-861-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Secondary-Power Distribution Assemblies | AMM 24-62-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Secondary-Power Distribution Assemblies | AMM 24-62-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Do a complete Aircraft power reset (EXT AC AVAIL light is OFF). Is the fault still present?
- If NO, do close out.
- If YES, continue with next step.
- Access the EMS CDU Signboard menu as follows:
- Push the SYSTEM - CNTL key.
- Push the lower left Line Select Key (LSK).
- Push the lower right LSK.
- Select "SPDA 2 IN".
- Record labels 353 to 356 in the table below:
Left Column Center Column 29 28 27 26 25 24 23 22 21 20 19 18 17 16 15 14 Label 353 Label 354 Label 355 Label 356
- Based on the labels and bits recorded previously (Bit(s) set to "1" only), swap SPDA 2 with the corresponding position marked with an "X" in the table below. By doing so, there is a chance that the ELEC SYS FAIL CAS message will become ELEC SYS FAULT instead.
Bit(s) set to "1" SPDA 1 SPDA 2 SPDA 3 SPDA 4 Label 353 Bit 28 X Label 354 Bit 15-16 X Label 355 Bit 25-24-23-21-20-19-17-16-15 X Label 356 Bit 29-28-27-25-24-23 X - Is the ELEC SYS FAIL CAS message posted? (the associated CAIMS message should reflect the new position of the failed SPDA).
- If YES, go to step 7.
- If NO, continue with next step.
- Is the ELEC SYS FAULT CAS message posted?
- If NO, do close out.
- If YES, continue with next step.
- Ensure that the ELEC SYS FAULT CAS message is related to the new position of SPDA 2. Is dispatch required?
- If YES, apply DDG conditions to allow dispatch and do close out.
- If NO, continue with next step.
- Replace SPDA 2.
- Do close out.