07/01/19
Message Overview:
Fault Message:
DCPC TLC1-TTC1 CONTACTOR-K1 PWR UP
Fault Code:
2463010DCP
Associated CAS:
| Reporting LRU: | DC Power Center (DCPC) |
| System Description: | 24-60-00 |
| Schematic Diagram: | 24-61-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 24-61-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
DC Power Center (DCPC) power on test will exercise one time the Transformer Rectifier Unit (TRU) Transfer Contactor (TTC) 1 side (K1) and compare the status with the commanded state. If they match the Contactor K1 is functional.
Possible Causes:
- DC Power Center (DCPC) Contactor (K1)
- DC Power Center (DCPC) Motherboard
- DC Power Center (DCPC) (A63)
- Electromagnetic Interference (EMI) Filter
- Electronic Module (EM1)
- Primary Logic Card (PLC) 1
- Primary Logic Card (PLC) 2
- Primary Logic Card (PLC) 3
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the DC Power Center (DCPC) | AMM 24-61-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) | AMM 24-61-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC) Primary Logic | AMM 24-61-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) Primary Logic | AMM 24-61-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC) L-Series Contactor | AMM 24-61-53-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) L-Series Contactor | AMM 24-61-53-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the DC Power Center (DCPC) Electronic Modules | AMM 24-61-65-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) Electronic Modules | AMM 24-61-65-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Get access to the DCPC contactor K1.
- Disconnect contactor K1 connector P104.
- In the cockpit, turn the BATT MSTR SW to ON.
- Perform a check for 28 VDC as follows:
From To Result P104-1 Ground P104-2 Ground - If there is no 28 VDC, go to step 14.
- If there is 28 VDC, continue with next step.
- Perform a wiring checks between AC Battery bus to EMI.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- In the cockpit, turn the BATT MSTR SW to OFF.
- Perform a continuity check between K1 and ground as follows:
From To Result P104-5 Ground P104-7 Ground - If there is no continuity, go to step 14.
- If there is continuity, continue with next step.
- Remove PLC 1, PLC 2 and PLC 3.
- Perform a continuity check with the connections that follows:
From To Result P104-6 Ground P104-8 Ground P104-22 Ground P104-3 Ground - If there is continuity, go to step 14.
- If there is no continuity, continue with next step.
- Replace contactor K1.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Re-install PLC 2 and PLC 3.
- If system checks are good, replace PLC 1 and do close out.
- If fault remains, continue with next step.
- Replace PLC 2.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace PLC 3.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace DCPC.
- Do close out.