Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/28/19

Message Overview:

Fault Message:

270 VDC LINK REGEN #2

Fault Code:

2750247STD

Associated CAS:

SLAT FLAP FAIL
(Caution)

Reporting LRU: Slat/Flap Control Unit (SFCU)
System Description: 27-52-00
Schematic Diagram: 27-50-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 27-50-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

When one of the conditions that follow occurs:

  • 270 VDC link internal to the Slat/Flap Control Unit (SFCU) is out of normal limits for more than 0.08 seconds OR,
  • There is an internal failure of the Motor Regenerative Resistor Circuit

Possible Causes:

  • Slat/Flap Control Unit (SFCU) 2 (A95)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

If the SLAT FLAP PWR 2 thermal breaker tripped on the CCBP, remove the SFCU#2.

Quick Links:

Removal of the Slat/Flap Control Unit (SFCU) AMM 27-51-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Slat/Flap Control Unit (SFCU) AMM 27-51-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to System Diagnostics AMM 45-45-00-970-804 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Access CAIMS System diagnostic and unlatch the fault in the SFCU 1.

    1. SYSTEM DIAG
    2. 27-00 FLIGHT CONTROLS
    3. SLAT/FLAP CONTROL UNIT #1(2)
    4. LRU TEST
    5. CLEAR LATCHED FAULT - SFCU 1
    6. Highlight “CLEAR LATCHED FAULTS” and “SELECT”

  2. On the EMS CDU, select CTRL function and SLAT/FLAP RESET.
    NOTE: Wait at least one minute after SFCU reset to allow self-test to run.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  3. Swap SFCU 2 with SFCU 1.
    NOTE: If necessary, unlatch the fault in CAIMS and perform a SLAT/FLAP RESET after swapping the SFCU’s.

    1. If system checks are good, replace SFCU 2 and do close out.
    2. If fault remains, continue with next step.

  4. Measure the AC voltage on the SFCU 2 and make sure the three phases are reading the same voltage.

    SFCU 2 Voltage
    A95BP1-6 115 VAC
    A95BP1-7 115 VAC
    A95BP1-8 115 VAC

    1. If voltages are the same, do close out.
    2. If voltages are different, continue with next step.

  5. Perform wiring checks between SFCU and CCBP. Repair as required.
  6. Do close out.