background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults By CAIMS By Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

06/27/19

Message Overview:

Fault Message:

OFFSIDE FLAP SYSTEM NOT RIGGED #1

Fault Code:

2751047STD

Associated CAS:

SLAT FLAP BIT
(Advisory)

Reporting LRU: Slat/Flap Control Unit (SFCU)
System Description: 27-52-00
Schematic Diagram: 27-50-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 27-50-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]
27-50-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]
27-50-05 [ Global Express ]  [ G5000 ]  [ Global XRS ]
27-50-06 [ Global Express ]  [ G5000 ]  [ Global XRS ]
27-50-07 [ Global Express ]  [ G5000 ]  [ Global XRS ]
27-50-08 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

From the offside Slat/Flap Control Unit (SFCU) when the rigging of the flap system is incorrect. The transmitted datafrom the Data Acquisition Unit (DAUs) does not compare with the data stored in the SFCU nonvolatile memory for the conditions that follow:

  • Out of tolerance rigging data
  • Dates that do not agree
  • Serial numbers that do not agree

This includes verification of the data transmitted from the onside SFCU.

Possible Causes:

  • Slat/Flap Control Unit (SFCU) 1 (A124)
  • Slat/Flap Control Unit (SFCU) 2 (A95)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Slat/Flap Control Unit (SFCU) AMM 27-51-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Slat/Flap Control Unit (SFCU) AMM 27-51-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Rigging of the Flap System AMM 27-52-00-820-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to System Diagnostics AMM 45-45-00-970-804 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to Aircraft Identification AMM 45-45-00-970-823 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Confirm the A/C identification is correct in CAIMS.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  2. If both SFCU's are reporting that the flaps are not rigged, perform a complete rigging of the flap system. It is important to perform the electrical rigging on the SFCU that is not reporting the fault because this will confirm the MIL-STD-1553 interface.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  3. Swap SFCUs and repair as required.
  4. Perform a flap electrical rigging on the SFCU that was not reporting the fault.
  5. Do close out.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.