07/03/19
Message Overview:
Fault Message:
LATCHED FAULT #2
Fault Code:
2752000STD
Associated CAS:
| Reporting LRU: | Slat/Flap Control Unit (SFCU) 2 |
| System Description: | 27-52-00 |
| Schematic Diagram: | 27-50-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-50-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Fault conditions that cannot be reset with the Slat/Flap Control Handle and is inhibiting the Slat and/or Flap System operation controlled by the Slat Flap Control Unit 2.
Possible Causes:
- Slat/Flap System
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW 700-27-0373 - SFCU -17: "SLAT-FLAP HALFSPD" EICAS Nuisance Message
Forum Articles/Infoservice/Newsletter: None
Criteria that can latch the SFCU:
- Slat/flap control handle fault (latched first time)
- Slat or flap motor over-temperature fault (latched second time)
- Under-speed fault or jam condition (latched third time)
- Invalid SFCU ID fault (latched first time)
- Uncommanded motion fault (latched third time)
- Over-speed fault (latched first time)
- Asymmetry fault (latched first time)
- Flap skew fault (latched first time)
- Slat motor wiring fault or flap motor wiring fault
Performing a SLAT FLAP RESET on the EMS CDU may clear this message.
The latched fault can be cleared by doing the AMM 27-51-05-910-801 "Clear Slat/Flap Control Unit (SFCU) Latched Faults".
Quick Links:
| Clear Slat/Flap Control Unit (SFCU) Latched Faults | AMM 27-51-05-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- When SFCU 1 or SFCU 2 is reporting another fault in CAIMS, perform the troubleshooting of the other CAIMS fault.
- Do close out.