Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/01/19

Message Overview:

Fault Message:

CROSS CHANNEL LINK FAILED #2

Fault Code:

2752041STD

Associated CAS:

SLAT FLAP BIT
(Advisory)

Reporting LRU: Slat/Flap Control Unit (SFCU)
System Description: 27-52-00
Schematic Diagram: 27-50-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 27-50-08 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

There is a bad communication in the MIL-STD-1553 interface between Slat/Flap Control Unit (SFCU) 1 and SFCU 2. This shows when there is disagreement between the input source of the cross channel communication.

Possible Causes:

  • Slat Flap Control Unit (SFCU) 2 (A95)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Slat/Flap Control Unit (SFCU) AMM 27-51-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Slat/Flap Control Unit (SFCU) AMM 27-51-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Perform wiring checks of the MIL-1553 interface between SFCU 1 and SFCU 2 as follow:

    From To Result
    A124AP1-74 A95AP1-73
    A124AP1-61 A95AP1-60
    A124AP1-73 A95AP1-74
    A124AP1-60 A95AP1-61

    1. If wiring checks are not good, repair defective wiring as required and do close out.
    2. If wiring checks are good, continue with next step.

  2. Replace SFCU 2.
  3. Do close out.