Message Overview:
Fault Message:
SLAT ACTUATION SYSTEM NOT RIGGED #2
Fault Code:
2752042STD
Associated CAS:
| Reporting LRU: | Slat Flap Control Unit (SFCU) |
| System Description: | 27-53-00 |
| Schematic Diagram: | 27-50-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-50-08 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
When the rigging of the Slat System is incorrect. The transmitted data from the Data Acquisition Units (DAU) does not compare with the data stored in the Slat/Flap Control Unit (SFCU) nonvolatile memory for the conditions that follow:
- Out of tolerance rigging data
- Dates that do not agree
- Serial numbers that do not agree
This includes verification of the data transmitted from the offside SFCU.
Possible Causes:
- Slat Flap Control Unit (SFCU) 1 (A124)
- Slat Flap Control Unit (SFCU) 2 (A95)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-45-0065 - CAIMS Nuisance Fault Messages
Forum Articles/Infoservice/Newsletter: None
This fault is normal if both SFCU’s have never been installed on the A/C. This fault is normal if an IAC was replaced and the A/C identification in CAIMS is not same then the A/C. The fault should clear after performing the installation procedure of the IAC.
Quick Links:
| Removal of the Slat/Flap Control Unit (SFCU) | AMM 27-51-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Slat/Flap Control Unit (SFCU) | AMM 27-51-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Rigging of the Leading Edge Slat-System | AMM 27-53-00-820-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to System Diagnostics | AMM 45-45-00-970-804 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Aircraft Identification | AMM 45-45-00-970-823 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Confirm the A/C identification is correct in CAIMS.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- If both SFCUs are reporting that the slats and flaps are not rigged, perform a complete rigging of the slats and flaps included in the AMM procedure for the SFCU installation.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Perform the slat rigging with the SFCU that is not reporting the fault in CAIMS.
- If system checks are good, do close out.
- If fault remains, continue with next step.
NOTE: It is very important to perform the electrical rigging on the SFCU that is not reporting the fault because this will confirm the cross talk communication busses integrity.
- Swap SFCUs.
- If system checks are good, replace defective SFCU and do close out.
- If fault remains, continue with next step.
- Perform wiring checks between the SFCU 1 and 2 cross talk communication busses. Repair as required.
- Do close out.