Message Overview:
Fault Message:
DISC INTF MOV DCPC/ SFCU#2/ WRG
Fault Code:
2752249STD
Associated CAS:
| Reporting LRU: | Slat Flap Control Unit (SFCU) 2 |
| System Description: | 27-52-00 |
| Schematic Diagram: | 27-50-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-50-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
MOVING 1/FLAPS IN MOTION discrete output from the Slat Flap Control Unit (SFCU) 2 is defective.
Possible Causes:
- DC Power Center (DCPC) (A63)
- DC Power Center (DCPC) Primary Logic Card (PLC) 1 (P110)
- DC Power Center (DCPC) Primary Logic Card (PLC) 2 (P210)
- DC Power Center (DCPC) Primary Logic Card (PLC) 3 (P310)
- Slat Flap Control Unit (SFCU) 2 (A95)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-45-0065 - CAIMS Nuisance Fault Messages
Forum Articles/Infoservice/Newsletter: None
The DCPC provides a 28 VDC discrete signal to the SFCU. The SFCU grounds this signal when the flap system is in motion. Performing a SLAT FLAP RESET on the EMS CDU may clear this fault.
NOTE: Wait at least one minute after SFCU reset to allow self test to run.
Quick Links:
| Removal of the DC Power Center (DCPC) | AMM 24-61-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) | AMM 24-61-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Slat/Flap Control Unit (SFCU) | AMM 27-51-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Slat/Flap Control Unit (SFCU) | AMM 27-51-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap SFCU 2 with SFCU 1 and confirm that they are installed properly and securely.
- If system checks are good replace SFCU 2 and do close out.
- If fault remains, continue with next step.
- Select a different Slat Flap Control Handle position.
- If system checks are good, do close out.
- If the fault remains, continue with next step.
- Remove SFCU 2 and verify 28 VDC on connector A95AP1-16.
- If 28 VDC is found, repair defective wiring as required and do close out.
- If 28 VDC is not found, continue with next step.
- Perform a wiring check on interface wire that follows:
From To Result A95AP1-16 A63P2-k - If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Remove the Primary Logic Cards one at a time, and apply aircraft power.
- If fault clears after removal of any one primary logic card, replace that Primary Logic Card and do close out.
- If fault still present, continue with next step.
- Remove all three DCPC Primary Logic Cards and perform a wiring check on interface that follows:
From To Expected Result Result P110B-6 A63P2-k Continuity P210B-6 A63P2-k Continuity P310B-6 A63P2-k Continuity Ground A63P2-k Open CAUTION: To prevent damage to the ACPC Mother Board connectors, ensure that the jumper wire pins outside diameter (OD) does not exceed 0.025 inch.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace DCPC.
- Do close out.