07/02/19
Message Overview:
Fault Message:
DISC INTF MOV2 FG PANEL/SFCU#2/ WRG
Fault Code:
2752250STD
Associated CAS:
| Reporting LRU: | Slat Flap Control Unit (SFCU) 2 |
| System Description: | 27-52-00 |
| Schematic Diagram: | 27-50-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-50-08 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
MOVING 2/SLATS IN MOTION discrete output from Slat Flap Control Unit (SFCU) 2 is defective.
Possible Causes:
- Slat Flap Control Unit (SFCU) 2 (A95)
- Guidance Control Panel (GCP) (A79)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-45-0065 - CAIMS Nuisance Fault Messages
Forum Articles/Infoservice/Newsletter: None
The Guidance panel provides a discrete signal to the SFCU. The SFCU grounds this signal when the slat system is in motion. Performing a SLAT FLAP RESET on the EMS CDU may clear this fault.
NOTE: Wait at least one minute after SFCU reset to allow self test to run.
Quick Links:
| Removal of the Guidance Control Panel | AMM 22-11-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Guidance Control Panel | AMM 22-11-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Slat/Flap Control Unit (SFCU) | AMM 27-51-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Slat/Flap Control Unit (SFCU) | AMM 27-51-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Swap SFCU 2 with SFCU 1 and confirm that they are installed properly and securely.
- If system checks are good, replace SFCU 2 and do close out.
- If fault remains, continue with next step.
- Select a different Slat Flap Control Handle position.
- If system checks are good, do close out.
- If the fault remains, continue with next step.
- Remove SFCU 2 and verify 28 VDC on connector A95AP1-15.
- If 28 VDC is not found, repair defective wiring as required and do close out.
- If 28 VDC is found, continue with next step.
- Perform a wiring check on interface wire that follows:
From To Result A95AP1-15 A79P1-FF - If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace Guidance Control Panel.
- Do close out.