07/05/19
Message Overview:
Fault Message:
FCM NOT POWERED [FCU #2]
Fault Code:
27657152SX
Associated CAS:
| Reporting LRU: | Flight Control Unit (FCU) 2 |
| System Description: | 27-60-00 |
| Schematic Diagram: | 27-60-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-60-06 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
A Flight Control Module in Flight Control Unit (FCU) 2 does not receive power during the CAIMS Interface Test.
Possible Causes:
- Flight-Control Unit (FCU) 2 (A66)
- Secondary Power Distribution Assembly (SPDA) 3 (A15)
- Secondary Power Distribution Assembly (SPDA) 4 (A16)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
CAIMS interface test can be initated as follows:
- SYSTEM DIAG
- 27-00 FLIGHT CONTROLS
- FLIGHT CONTROL UNIT #2
- LRU TEST
- FLT CONTROL UNIT #2 INTERFACE TEST
- Confirm
Quick Links:
| Removal of the DC Power Center (DCPC) Secondary-Power Distribution Assembly (SPDA) Feeder |
AMM 24-61-37-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) Secondary-Power Distribution Assembly (SPDA) Feeder |
AMM 24-61-37-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Flight-Control Units | AMM 27-61-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Flight-Control Units | AMM 27-61-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to System Diagnostics | AMM 45-45-00-970-804 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Re-rack FCU 2.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Swap FCU 2 with FCU 1.
- If system checks are good, replace FCU 2. Reset FCUs latched faults and do close out.
- If fault remains, continue with next step.
- Measure for 28 VDC at FCU 2 and confirm voltage is not fluctuating.
FCU 2 Expected Result Result A66CP1-11 28 VDC A66CP1-7 28 VDC A66FP1-11 28 VDC A66FP1-7 28 VDC - If checks are good, do close out.
- If any of the checks fails, continue with next step.
- Confirm/Measure steady 28 VDC from corresponding SPDA by removing pin from SPDA's connector as follow:
From To Expected Result Result A66CP1-11 A15P3-f 28 VDC A66CP1-7 Ground 28 VDC A66FP1-11 A16P3-p 28 VDC A66FP1-7 Ground 28 VDC - If check fails, go to step 6.
- If checks are good, continue.
- Perform wiring checks between FCU and corresponding SPDA.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace defective SPDA.
- Do close out.