background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults By CAIMS By Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/09/19

Message Overview:

Fault Message:

FCU #2/ INTERNAL BUS FAULT [FCM B]

Fault Code:

27660262SX

Associated CAS:

SPLRS STAB BIT
(Advisory)

Reporting LRU: Flight-Control Unit (FCU) 2
System Description: 27-60-00
Schematic Diagram: 27-60-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 27-60-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

Internal failure causing loss of redundancy data but depends on bus affected. May cause Flight-Control Unit (FCU) channel B invalid.

Possible Causes:

  • Flight-Control Unit (FCU) 2 (A66)

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

This fault may sometime be cleared by performing the flight control system reset procedure.

Quick Links:

Removal of the Flight-Control Units AMM 27-61-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Flight-Control Units AMM 27-61-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. If you have another CAIMS fault perform this fault first.
  2. Access the system diagnostic and run “FCU INTERFACE TEST” from LRU test menu.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  3. Replace FCU 2 and reset FCUs latched faults.
  4. Do close out.