07/10/19
Message Overview:
Fault Message:
H STAB MOTOR #2/ACT/WRG FAULT
Fault Code:
27662222SX
Associated CAS:
| Reporting LRU: | Flight Control Unit (FCU) 2 |
| System Description: | 27-40-00 |
| Schematic Diagram: | 27-41-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-41-02 [ Global Express ] [ G5000 ] [ Global XRS ] 27-41-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
There is a problem with the Motor Brake that could be detected either during flight or aircraft power-up.
Possible Causes:
- Pitch Trim Actuator Motor Drive Unit (MDU) (A184)
- Flight Control Unit (FCU) 2 (A66)
- Pitch Trim Actuator (PTA) (B44)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
This fault may sometime be cleared by performing the flight control system reset procedure.
The pitch trim brake status can found in CAIMS:
Quick Links:
| Removal of the Pitch Trim Actuator | AMM 27-41-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Pitch Trim Actuator | AMM 27-41-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Pitch Trim Actuator-Motor | AMM 27-41-13-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Pitch Trim Actuator-Motor | AMM 27-41-13-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Flight-Control Units | AMM 27-61-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Flight-Control Units | AMM 27-61-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- If the message H STAB MOTOR #2/ACT/WRG FAULT is reported by the FCU 1 and FCU 2 replace the pitch trim actuator motor 2.
- Swap FCU 2 with FCU 1.
- If system checks are good, replace FCU 2. Reset FCUs latched faults and do close out.
- If fault remains, continue with next step.
- If the fault is reported by the FCU 1 measures the impedance between the FCU 1 to the Motor 2. If the fault is reported by the FCU 2 measures the impedance between the FCU 2 to the Motor 2. Make sure the impedance is not less than 60 Ω for a short circuit to ground and not more than 90 Ω for an open circuit.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Perform a wiring checks between the FCUs to the motor 2.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace Pitch Trim Actuator Motor.
- Do close out.