Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/12/19

Message Overview:

Fault Message:

GROUND RDCP/WRG

Fault Code:

2844604PK

Associated CAS:

None

Reporting LRU: Fuel Management and Quantity Gauging Computer (FMQGC)
System Description: 28-23-00
Schematic Diagram: 28-23-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 28-23-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

The Fuel Management Quantity and Gauging Computer (FMQGC) cannot sense the REFUEL/DEFUEL Control Panel (RDCP) data busses.

Possible Causes:

  • Junction Box (JB6)/PCB1
  • Junction Box (JB6)/PCB3
  • Auxiliary Power Unit (APU) Start Contactor Assembly (ACSA) (A48)
  • Refuel/Defuel Control Panel (RDCP) (A46)
  • Refuel/Defuel Control Panel (RDCP) (A213)
  • Fuel Management Quantity and Gauging Computer (FMQGC) (A47)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

  • 700-28-002 - Modification - Refuel/Defuel System - Addition of Refuel/Defuel Control Panel in Flight Compartment

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Connect Electrical Power to the Aircraft AMM 24-00-00-861-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Remove the Electrical Power from the Aircraft AMM 24-00-00-861-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Opening of Non-Thermal Circuit Breakers AMM 24-00-00-863-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Closing of Non-Thermal Circuit Breakers AMM 24-00-00-863-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Electrical/Electronic Safety Precautions AMM 24-00-00-910-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Junction Box JB6 Circuit-Cards AMM 24-00-14-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Junction Box JB6 Circuit-Cards AMM 24-00-14-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the REFUEL/DEFUEL Control Panel AMM 28-23-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the REFUEL/DEFUEL Control Panel AMM 28-23-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Operational Test of the Refuel/Defuel Control Panel AMM 28-23-01-710-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Computer AMM 28-41-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Computer AMM 28-41-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to Active Faults AMM 45-45-00-970-802 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Safety Precautions - Maintenance Practices - ALL SPM 20-00-01-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. In the CAIMS PMAT navigate to check the status of the ground Refuel Defuel Control Panel (RDCP).

    1. CAIMS
    2. System Diagnostics
    3. 28-00 Fuel
    4. Computer (FMQGC CH. A(B))
    5. LRU TEST
    6. RDCP AND REFUEL VALVES DATA - CH. A

  2. Go to page 2 for the RDCP AND REFUEL VALVES DATA - CH. A data page. Turn ON the ground RDCP panel.

    1. If the CAIMS does the discrete display OFF, go to step 4.
    2. If the CAIMS discrete displays ON, continue with next step.

  3. Swap the Cockpit RDCP with the Ground RDCP.
    NOTE: If A/C has dual RDCP's then complete this step, If not go to next step.

    1. If system checks are good, replace Cockpit RDCP and do close out.
    2. If fault remains, continue with next step.

  4. Disconnect connector A46P1 at the ground RDCP. Add a jumper wire and connect to pins 2 and 3. Perform wiring check as follows:

    From To Expected Result Result
    A46P1-12 A46P1-18 28 VDC
    A46P1-13 A46P1-17 28 VDC
    A46P1-18 Airframe Ground Continuity
    A46P1-17 Airframe Ground Continuity

    1. If wiring checks are good, go to step 6.
    2. If wiring checks are not good, repair defective wiring as required and continue with next step.

  5. Reconnect A46P1 at the ground RDCP. Perform wiring check at the APU Start Contactor Assembly (ASCA).

    From To Expected Result Result
    A48J1-T Airframe Ground 28 VDC
    A48J1-U Airframe Ground 28 VDC

    1. If wiring checks are not good, replace CB-A1 or CB-A3 or suspect the (ASCA) and do close out.
    2. If wiring checks are good, continue with next step.

  6. Perform wiring check at JB6 for PCB1.

    From To Expected Result Result
    TP-60 TP-30 28 VDC
    TP-61 TP-30 28 VDC
    TP 59 TP-30 28 VDC
    TP-30 Airframe ground Continuity

    1. If TP-30 does not have a ground, repair GS67 or repair defective wiring and do close out.
    2. If TP-59 has power and TP-61 does not have power, replace PCB1 in JB6 and do close out.
    3. If TP-59 does not have 28 VDC, repair wiring to FMQGC or replace FMQGC and do close out.
    4. If wiring checks are good, continue with next step.

  7. Perform wiring check at JB6 for PCB3.

    From To Expected Result Result
    TP-31 Airframe ground 28 VDC
    TP-56 Airframe ground Ground

    1. If wiring checks are not good, replace PCB3 in JB6 or repair defective wiring and do close out.
    2. If wiring checks are good, continue with next step.

  8. Turn OFF aircraft power and rerack the FMQGC making sure it is fully and properly pushed into place. Is the fault still present?

    1. If NO, do close out.
    2. If YES, continue with next step.

  9. Replace the FMQGC.
  10. Do close out.