Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/12/19

Message Overview:

Fault Message:

LH AFT AC BOOST PUMP ELECT PWR/WRG

Fault Code:

2844606PK

Associated CAS:

L PRI FUEL PUMPS
(Caution)

L PRI FUEL PUMP
(Advisory)

Reporting LRU: Fuel Management and Quantity Gauging Computer (FMQGC)
System Description: 28-21-00
Schematic Diagram: 28-21-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 28-21-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

Fuel Management Quantity and Gauging Computer (FMQGC) senses that the Left Wing Aft AC Boost-Pump is not able to go off or on as commanded due to an Electrical Load Management System (LMS) failure.

Possible Causes:

  • AC Power Center (ACPC)/Solid-State Power Controller (SSPC) 1 (A2)
  • AC Power Center (ACPC) Secondary Logic Card (A7)
  • Left Aft AC Boost Pump Cartridge (B7)
  • Fuel Management Quantity and Gauging Computer (FMQGC) (A47)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Article/Infoservice/Newsletter: None

NOTE: If both of the CAIMS messages L AFT AC BOOST PUMP/WRG FAULT and L AFT AC BOOST PUMP LMS/WRG FAULT are displayed, troubleshoot with L AFT AC BOOST PUMP/WRG FAULT page first.

Quick Links:

Electrical/Electronic Safety Precautions AMM 24-00-00-910-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the AC Power Center (ACPC) Secondary Logic AMM 24-51-13-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the AC Power Center (ACPC) Secondary Logic AMM 24-51-13-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the AC Power Center (ACPC) Solid-State Power Controller AMM 24-51-53-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the AC Power Center (ACPC) Solid-State Power Controller AMM 24-51-53-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the AC Boost-Pump Cartridges AMM 28-21-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the AC Boost-Pump Cartridges AMM 28-21-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the AC Boost-Pump Canisters AMM 28-21-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the AC Boost-Pump Canisters AMM 28-21-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Computer AMM 28-41-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Computer AMM 28-41-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to System Diagnostics AMM 45-45-00-970-804 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Using the PMAT, access CAIMS, SYSTEM DIAG. Select ATA 24, ACPC A (B), LOAD STATUS LABEL 002, LOAD 1 (L AFT PRI PUMP, Phase A) page. Set the left ENGINE RUN switch to ON and the L PRI PUMPS switch/light to ON (Pushed out). Make sure the result that follows are met:

      Reference Status
      LOGIC EQUATION STATE (L TRANSFER REQUEST) ON
      VIRTUAL CIRCUIT BREAKER (SSPC CIRCUIT BREAKER) IN
      VIRTUAL SWITCH (SSPC SW) ON
      LOCK STATE UNLOCKED
      VOLTAGE STATUS PRESENT
      CURRENT STATUS FLOWING
      TRIP STATUS (CIRCUIT BREAKER) NOT TRIP
      FAIL STATUS (SSPC) NOT FAILED

    1. If all of the above status are met, go to step 8.
    2. If one or more of the above status is not met, go to step 3.
    3. NOTE: Repeat this step by selecting LABEL 002 Load 2 (L AFT PRI PUMP, Phase B) and LABEL 003 Load 1 (L AFT PRI PUMP, Phase C).

  2. An alternative way of monitoring the result is to select ACPC IN via EMS CDU1 or CDU2 Signboard Menu:

      Left column Center column
      Label 002
      29 28 27 26 25 24 23 22
      1 1 1 1 1 1
      21 20 19 18 17 16 15 14
      1 1 1 1 1 1
      Reference L AFT PRIM PUMP Phase B L AFT PRIM PUMP Phase A
      Label 003
      29 28 27 26 25 24 23 22
      X X X X X X X X
      21 20 19 18 17 16 15 14
      1 1 1 1 1 1
      Reference L AFT PRIM PUMP Phase C

    • Built-In Test (BIT) 14 or 22:LOGIC EQUATION STATE (L TRANSFER REQUEST)
    • Built-In Test (BIT) 15 or 23:VIRTUAL CIRCUIT BREAKER (SSPC CIRCUIT BREAKER)
    • Built-In Test (BIT) 16 or 24:VIRTUAL SWITCH (SSPC SW)
    • Built-In Test (BIT) 17 or 25:LOCK STATE
    • Built-In Test (BIT) 18 or 26:VOLTAGE STATUS
    • Built-In Test (BIT) 19 or 27:CURRENT STATUS
    • Built-In Test (BIT) 20 or 28:TRIP STATUS (CIRCUIT BREAKER)
    • Built-In Test (BIT) 21 or 29:FAIL STATUS (SSPC)

    1. If the above status are met, go to step 8.
    2. If one or more of the above status is not met, continue with next step.

  3. Perform wiring check (short to ground=fail) between the ACPC (A54P5) and left wing aft AC boost-pump (B7P1).

    1. If wiring checks are not good, repair defective wiring as required and do close out.
    2. If wiring checks are good, continue with next step.

  4. Perform a ground check at left wing aft AC boost-pump (B7J1). Repair as required.

    1. If ground is not present, go to step 6.
    2. If ground is present, continue with next step.

  5. Swap the left wing AC boost-pump. Is the fault still present?

    1. If NO, replace left wing AC boost-pump and do close out.
    2. If YES, continue with next step.

  6. Swap the ACPC/SSPC 1 (A2). Is the fault still present?

    1. If NO, replace ACPC/SSPC 1 (A2) and do close out.
    2. If YES, continue with next step.

  7. Swap the ACPC Secondary Logic Card (SLC) (A7). Is the fault still present?

    1. If NO, replace ACPC Secondary Logic Card (SLC) (A7) and do close out.
    2. If YES, continue with next step.

  8. Remove the FMQGC. Re-install the FMQGC making sure it is fully and properly inserted into place. Is the fault still present?

    1. If NO, do close out.
    2. If YES, continue with next step.

  9. Replace FMQGC.
  10. Do close out.