05/12/22
Message Overview:
Message Name:
LH ENG FEED SOV ELECT PWR /WRG
Message Code:
2844618PK
Associated CAS:
| Reporting LRU: | Fuel Management and Quantity Gauging Computer (FMQGC) |
| System Description: | 28-21-00 |
| Schematic Diagram: | 28-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 28-21-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Mesage Description:
L ENG FEED VALVE LMS/WRG FAULT shows when the conditions that follow occur:
- The Left Engine Fire-Handle is pulled.
- The Left Engine-Feed Shutoff-Valve is open.
- The Electrical Management System (EMS)/DC Power Center (DCPC) has a failure.
OR,
- The Left Engine Fire-Handle is not pulled.
- The Left Engine-Feed Shutoff-Valve is closed.
- The EMS/DCPC has a failure.
Possible Causes:
- DC Power Center (DCPC) (A63)
- Left Engine Fuel Shut-off Valve (CB-A3)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the DC Power Center (DCPC) | AMM 24-61-00-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the DC Power Center (DCPC) | AMM 24-61-00-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Electrical Management System Control-and-Display Units (EMS CDU) | AMM 24-70-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Electrical Management System Control-and-Display Units (EMS CDU) | AMM 24-70-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Computer | AMM 28-41-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Computer | AMM 28-41-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Using CAIMS, verify if messages related to the 28 VDC emergency bus or DCPC are shown:
- If YES, troubleshoot them first and continue with next step.
- If NO, continue with next step.
- Using CAIMS, select SYSTEM DIAG - ATA 24 - DCPC A(B) - LRU TEST - LOAD STATUS and verify the Circuit Breaker (CB) status.
- If the CB status is IN, continue with next step.
- If the CB is OUT/TRIPPED go to Observed fault 245OBS001 - THERMAL CIRCUIT BREAKER TRIPPED and perform troubleshooting.
- Check for 28 VDC at DCPC connector A63P3-B.
- If 28 VDC is present, continue with next step.
- If voltage is not present, go to step 5.
- Disconnect the the L ENG SOV connector L38P1 and perform a 28 VDC voltage check as follows:
From To Expected Result Result L38P1-D Ground 28 VDC NOTE: Make sure the Fire Handle is pushed IN
- If voltage is present, replace the L ENG SOV.
- If voltage is not present, perform a wiring check between the DCPC and the L ENG SOV and repair defective wiring if required.
- Replace the L ENG FUEL SOV circuit breaker (CB-A3).
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the DCPC.
- Do close out.