07/16/19
Message Overview:
Fault Message:
RH AFT XFER SOV CL ELECT PWR/WRG
Fault Code:
2844632PK
Associated CAS:
| Reporting LRU: | Fuel Management and Quantity Gauging Computer (FMQGC) |
| System Description: | 28-22-00 |
| Schematic Diagram: | 28-22-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 28-22-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Right AFT Transfer Valve is commanded closed and the valve remains open due to:
- A failure of the Electrical System
- A failure of the valve command signal from the Fuel Management and Quantity Gauging Computer (FMQGC) to the Electrical Management System Control-and-Display Unit (EMS CDU)
Possible Causes:
- Secondary Power Distribution Assembly (SPDA) 3 (A15)
- Electrical Management System Control-and-Display Units (EMS CDU) 1 (A94)
- Electrical Management System Control-and-Display Units (EMS CDU) 2 (A91)
- Right Aft Transfer Shutoff-Valve (L37)
- AFT XFER Rotary Switch (S2)
- Fuel Management and Quantity Gauging Computer (FMQGC) (A47)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
- AW700-45-0065 - CAIMS Nuisance Fault Messages
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Secondary-Power Distribution Assemblies | AMM 24-62-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Secondary-Power Distribution Assemblies | AMM 24-62-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Electrical Management System Control-and-Display Units (EMS CDU) |
AMM 24-70-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Electrical Management System Control-and-Display Units (EMS CDU) |
AMM 24-70-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Aft Transfer Shutoff-Valves | AMM 28-22-33-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Aft Transfer Shutoff-Valves | AMM 28-22-33-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Computer | AMM 28-41-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Computer | AMM 28-41-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Disconnect the right aft transfer SOV connector L37P1. Apply power to the A/C. Set the AFT XFER knob on the Fuel Control Panel to "ON". Perform voltage check as follows:
Right aft transfer SOV Expected Result Result L37P1-D 28 VDC - If the results are not as described in the table above, go to step 6.
- If the results are as described in the table above, continue with the next step.
- Remove power from the A/C. Remove the FMQGC and perform a continuity check as follows:
From To Result L37P1-G A47DP1-F13 L37P1-F A47DP1-G13 - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Perform a continuity check as follows:
From To Result L37P1-G Ground L37P1-F Ground - If there is continuity, repair defective wiring as required and do close out.
- If there is no continuity, continue with next step.
- Re-install the FMQGC making sure it is fully and properly inserted into the tray. Is the fault still present?
- If NO, do close out.
- If YES, continue with next step.
- Swap the Right Aft Transfer SOV with the Left Aft Transfer SOV. Is the fault still present?
- If YES, go to step 11.
- If NO, replace Right Aft Transfer SOV and do close out.
- Remove power from the A/C. Disconnect SPDA 3 connector A15P4. Perform a continuity check as follows:
From To Result L37P1-B A15P4-B L37P1-D A15P4-A - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Perform a continuity check as follows:
From To Result L37P1-B Ground L37P1-D Ground - If there is continuity, repair defective wiring as required and do close out.
- If there is no continuity, continue with next step.
- Swap SPDA 3 with SPDA 2. Is the fault still present?
- If NO, replace SPDA 3 and do close out.
- If YES, continue with next step.
- Disconnect EMS CDU 1 and test the system again. Is the fault still present?
- If NO, replace EMS CDU 1 and do close out.
- If YES, continue with next step.
- Reconnect EMS CDU 1 and disconnect EMS CDU 2. Test the system again. Is the fault still present?
- If NO, replace EMS CDU 2 and do close out.
- If YES, continue with next step.
- Replace the FMQGC.
- Do close out.