Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/16/19

Message Overview:

Fault Message:

LH AFT XFER SOV/WRG

Fault Code:

2844633PK

Associated CAS:

AFT XFER FAIL
(Caution)

AFT XFER FAULT
(Advisory)

Reporting LRU: Fuel Management and Quantity Gauging Computer (FMQGC)
System Description: 28-22-00
Schematic Diagram: 28-22-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 28-21-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

Left AFT Transfer Valve is not in the position commanded and the Electrical System has not failed. The valve is commanded open and the valve is not fully open, or the valve is commanded closed and the valve is not fully closed.

Possible Causes:

  • Secondary Power Distribution Assembly (SPDA) 2 (A14)
  • Electrical Management System Control-and-Display Units (EMS CDU) 1 (A94)
  • Electrical Management System Control-and-Display Units (EMS CDU) 2 (A91)
  • Left Aft-Transfer Shut-off Valve (L36)
  • AFT XFER Rotary Switch (S2)
  • Fuel Management and Quantity Gauging Computer (FMQGC) (A47)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Secondary-Power Distribution Assemblies AMM 24-62-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Secondary-Power Distribution Assemblies AMM 24-62-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Electrical Management System
Control-and-Display Units (EMS CDU)
AMM 24-70-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Electrical Management System
Control-and-Display Units (EMS CDU)
AMM 24-70-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Aft Transfer Shutoff-Valves AMM 28-22-33-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Aft Transfer Shutoff-Valves AMM 28-22-33-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Computer AMM 28-41-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Computer AMM 28-41-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to Stored Faults AMM 45-45-00-970-803 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Switch/Light SPM 20-11-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Switch/Light SPM 20-11-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Disconnect the left aft transfer SOV connector L36P1. Apply power to the A/C. Set the AFT XFER knob on the Fuel Control Panel to 'ON'. Perform a voltage check as follows:

    Left aft transfer SOV Expected Result Result
    L36P1-D 28 VDC

    1. If the results are not as described in the table above, go to step 7.
    2. If the results are as described in the table above, continue with the next step.

  2. Set the AFT XFER knob on the Fuel Control Panel to 'OFF'. Perform a voltage check as follows:

    Left aft transfer SOV Expected Result Result
    L36P1-B 28 VDC

    1. If the results are not as described in the table above, go to step 7.
    2. If the results are as described in the table above, continue with the next step.

  3. Remove power from the A/C. Remove the FMQGC and perform a continuity check as follows:

    From To Result
    L36P1-G A47AP1-G14
    L36P1-F A47AP1-H14

    1. If there is no continuity, repair defective wiring as required and do close out.
    2. If there is continuity, continue with next step.

  4. Perform a continuity check as follows:

    From To Result
    L36P1-G Ground
    L36P1-F Ground

    1. If there is continuity, repair defective wiring as required and do close out.
    2. If there is no continuity, continue with next step.

  5. Re-install the FMQGC making sure it is fully and properly inserted into the tray. Is the fault still present?

    1. If NO, do close out.
    2. If YES, continue with next step.

  6. Swap the left aft transfer SOV with the right aft transfer SOV. Is the fault still present?

    1. If YES, go to step 15.
    2. If NO, replace the defective Aft Transfer SOV and do close out.

  7. Remove power from the A/C. Remove the FMQGC. Remove EMS CDU 1 and EMS CDU 2. Remove the Fuel Control Panel. Perform a continuity check as follows:

    From To Result
    AP5P1-15 Ground
    AP5P2-18 Ground
    AP5P2-25 Ground
    AP5P2-36 A47DP1-C13
    AP5P2-39 A47DP1-D13
    AP5P2-46 A47DP1-E13
    AP5P2-44 A91P1-42
    AP5P2-54 A91P1-66
    AP5P2-53 A91P2-42
    AP5P2-55 A91P2-66
    AP5P1-44 A94P1-42
    AP5P1-54 A94P1-66
    AP5P1-53 A94P2-42
    AP5P1-55 A94P2-66

    1. If there is no continuity, repair defective wiring as required and do close out.
    2. If there is continuity, continue with next step.

  8. Perform a continuity check as follows:

    From To Result
    AP5P2-36 Ground
    AP5P2-39 Ground
    AP5P2-46 Ground
    AP5P2-44 Ground
    AP5P2-54 Ground
    AP5P2-53 Ground
    AP5P2-55 Ground
    AP5P1-44 Ground
    AP5P1-54 Ground
    AP5P1-53 Ground
    AP5P1-55 Ground

    1. If there is continuity, repair defective wiring as required and do close out.
    2. If there is no continuity, continue with next step.

  9. Perform a continuity check directly on the Fuel Control Panel with the AFT XFER switch in various positions as follows:

    Fuel Control Panel Switch position
    From To Auto ON OFF
    AP5J2-36 AP5J2-25 Continuity Open Open
    AP5J2-39 AP5J2-25 Open Continuity Open
    AP5J2-46 AP5J2-25 Open Open Continuity
    AP5J2-44 AP5J1-15 Open Continuity Open
    AP5J2-54 AP5J1-15 Open Continuity Open
    AP5J2-53 AP5J1-15 Open Continuity Open
    AP5J2-55 AP5J1-15 Open Continuity Open
    AP5J1-44 AP5J2-18 Open Continuity Open
    AP5J1-54 AP5J2-18 Open Continuity Open
    AP5J1-53 AP5J2-18 Open Continuity Open
    AP5J1-55 AP5J2-18 Open Continuity Open

    1. If the continuity check results are not as per the table above, replace the AFT XFER switch or the Fuel Control Panel as required and do close out.
    2. If the continuity check results are as per the table above, continue with next step.

  10. Disconnect SPDA 2 connector A14P2. Perform a continuity check as follows:

    From To Result
    L36P1-B A14P2-E
    L36P1-D A14P2-D

    1. If there is no continuity, repair defective wiring as required and do close out.
    2. If there is continuity, continue with next step.

  11. Perform a continuity check as follows:

    From To Result
    L36P1-B Ground
    L36P1-D Ground

    1. If there is continuity, repair defective wiring as required and do close out.
    2. If there is no continuity, continue with next step.

  12. Swap SPDA 2 with SPDA 3. Is the fault still present?

    1. If NO, replace SPDA 2 and do close out.
    2. If YES, continue with next step.

  13. Disconnect EMS CDU 1, leaving EMS CDU 2 connected and test the system again. Is the fault still present?

    1. If NO, replace EMS CDU 1 and do close out.
    2. If YES, continue with next step.

  14. Reconnect EMS CDU 1 and disconnect EMS CDU 2. Test the system again. Is the fault still present?

    1. If NO, replace EMS CDU 2 and do close out.
    2. If YES, continue with next step.

  15. Replace the FMQGC.
  16. Do close out.