Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

10/23/20

Message Overview:

Fault Message:

XFEED SOV/WRG

Fault Code:

2844636PK

Associated CAS:

XFEED VALVE FAIL
(Advisory)

Reporting LRU: Fuel Management and Quantity Gauging Computer (FMQGC)
System Description: 28-21-00
Schematic Diagram: 28-21-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 28-21-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

XFEED VALVE/WRG FAULT shows when the conditions that follow occur:

  1. The XFEED SOV Pushbutton on the FUEL Control Panel is not set to OPEN
  2. The indication is that the Crossfeed Shut-off Valve is open
  3. There is no failure with the Electrical Management System (EMS)/Secondary Power Distribution Assembly (SPDA)

OR

  1. The XFEED SOV Pushbutton on the FUEL Control Panel is set to OPEN
  2. The indication is that the Crossfeed Shut-off Valve is closed
  3. There is no failure with the EMS/SPDA

OR

  1. The indication is that the Crossfeed Shut-off Valve is open and closed at the same time
  2. There is no failure with the EMS/SPDA

Possible Causes:

  • Crossfeed Shut-Off Valve (L34)
  • Fuel Control Panel (AP5)
  • Fuel Management and Quantity Gauging Computer (FMQGC) (A47)
  • Secondary Power Distribution Assembly (SPDA) 2 (A14)
  • Crossfeed Shut-off Valve Switch (SDS3)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Secondary-Power Distribution Assemblies AMM 24-62-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Secondary-Power Distribution Assemblies AMM 24-62-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the FUEL Control Panel AMM 28-20-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the FUEL Control Panel AMM 28-20-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Crossfeed Shut-off Valve AMM 28-21-45-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Crossfeed Shut-off Valve AMM 28-21-45-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Crossfeed Shut-off Valve Actuator AMM 28-21-49-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Crossfeed Shut-off Valve Actuator AMM 28-21-49-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Computer AMM 28-41-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Computer AMM 28-41-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to Stored Faults AMM 45-45-00-970-803 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Switch/Lights and Bulbs - Removal/Installation SPM 20-11-05-04 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Use the PMAT to access CAIMS -  SYSTEM DIAG - ATA 28 - FMQGC A (B)-CH A (B) - LRU TEST and select the COCKPIT FUEL PANEL DATA page, make sure the results that follow are met with the XFEED SOV PBA set to open (pushed in):

    Reference Status
    XFEED VALVE OPEN STATE OPEN
    XFEED VALVE CLOSED STATE NOT CLOSED

    1. If one of the above status is not met, go to step 3.
    2. If all the above status are met, continue with next step.

  2. Use the PMAT to access CAIMS -  SYSTEM DIAG - ATA 28 - FMQGC A (B)-CH A (B) - LRU TEST and select the COCKPIT FUEL PANEL DATA page, make sure the results that follow are met with the XFEED SOV PBA set to closed (pushed out):

    Reference Status
    XFEED VALVE OPEN STATE NOT OPEN
    XFEED VALVE CLOSED STATE CLOSED

    1. If all the above status are met, go to step 15.
    2. If one of the above status is not met, continue with next step.

  3. Perform wiring check between the crossfeed SOV (L34P1) and FMQGC (A47AP1).

    1. If wiring checks are not good, repair defective wiring as required and do close out.
    2. If wiring checks are good, continue with next step.

  4. Check for 28 VDC at crossfeed SOV (L34P1).

    1. If voltage is not there, go to step 7.
    2. If voltage is there, continue with next step.

  5. Replace the crossfeed SOV actuator (L34P1).

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  6. Replace the crossfeed SOV (L34P1).

    1. If system checks are good, do close out.
    2. If fault remains, go to step 15.

  7. Check for 28 VDC at SPDA 2 (A14P1).

    1. If voltage is not there, go to step 9.
    2. If voltage is there, continue with next step.

  8. Perform a wiring check between SPDA 2 (A14P1) and the crossfeed SOV (L34P1).

    1. If wiring checks are not good, repair defective wiring as required and do close out.
    2. If wiring checks are good, continue with next step.

  9. Check for ground at EMS CDU (A91P2) (A94P2).

    1. If ground is there, go to step 14.
    2. If ground is not there, continue with next step.
      NOTE: A ground is sent to both EMS CDU when the XFEED SOV PBA is set to open (pushed in).

  10. Perform wiring check between ground stud (GS852) and FUEL control panel (AP5P1).

    1. If wiring checks are not good, repair defective wiring as required and do close out.
    2. If wiring checks are good, continue with next step.

  11. Perform wiring check between FUEL control panel (AP5P1), XFEED SOV PBA (SDS3) and EMS CDU (A91P2) (A94P2).

    1. If wiring checks are not good, repair defective wiring as required and do close out.
    2. If wiring checks are good, continue with next step.

  12. Replace the XFEED SOV PBA (SDS3).

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  13. Replace the FUEL control panel (AP5).

    1. If system checks are good, do close out.
    2. If fault remains, go to step 15.

  14. Swap the SPDA 2 with SPDA 3.

    1. If system checks are good, replace SPDA 2 and do close out.
    2. If fault remains, continue with next step.

  15. Replace FMQGC.
  16. Do close out.