Message Overview:
Fault Message:
XFEED SOV/WRG
Fault Code:
2844636PK
Associated CAS:
| Reporting LRU: | Fuel Management and Quantity Gauging Computer (FMQGC) |
| System Description: | 28-21-00 |
| Schematic Diagram: | 28-21-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 28-21-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
XFEED VALVE/WRG FAULT shows when the conditions that follow occur:
- The XFEED SOV Pushbutton on the FUEL Control Panel is not set to OPEN
- The indication is that the Crossfeed Shut-off Valve is open
- There is no failure with the Electrical Management System (EMS)/Secondary Power Distribution Assembly (SPDA)
OR
- The XFEED SOV Pushbutton on the FUEL Control Panel is set to OPEN
- The indication is that the Crossfeed Shut-off Valve is closed
- There is no failure with the EMS/SPDA
OR
- The indication is that the Crossfeed Shut-off Valve is open and closed at the same time
- There is no failure with the EMS/SPDA
Possible Causes:
- Crossfeed Shut-Off Valve (L34)
- Fuel Control Panel (AP5)
- Fuel Management and Quantity Gauging Computer (FMQGC) (A47)
- Secondary Power Distribution Assembly (SPDA) 2 (A14)
- Crossfeed Shut-off Valve Switch (SDS3)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Secondary-Power Distribution Assemblies | AMM 24-62-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Secondary-Power Distribution Assemblies | AMM 24-62-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the FUEL Control Panel | AMM 28-20-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the FUEL Control Panel | AMM 28-20-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Crossfeed Shut-off Valve | AMM 28-21-45-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Crossfeed Shut-off Valve | AMM 28-21-45-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Crossfeed Shut-off Valve Actuator | AMM 28-21-49-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Crossfeed Shut-off Valve Actuator | AMM 28-21-49-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Computer | AMM 28-41-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Computer | AMM 28-41-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Stored Faults | AMM 45-45-00-970-803 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Switch/Lights and Bulbs - Removal/Installation | SPM 20-11-05-04 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Use the PMAT to access CAIMS - SYSTEM DIAG - ATA 28 - FMQGC A (B)-CH A (B) - LRU TEST and select the COCKPIT FUEL PANEL DATA page, make sure the results that follow are met with the XFEED SOV PBA set to open (pushed in):
Reference Status XFEED VALVE OPEN STATE OPEN XFEED VALVE CLOSED STATE NOT CLOSED - If one of the above status is not met, go to step 3.
- If all the above status are met, continue with next step.
- Use the PMAT to access CAIMS - SYSTEM DIAG - ATA 28 - FMQGC A (B)-CH A (B) - LRU TEST and select the COCKPIT FUEL PANEL DATA page, make sure the results that follow are met with the XFEED SOV PBA set to closed (pushed out):
Reference Status XFEED VALVE OPEN STATE NOT OPEN XFEED VALVE CLOSED STATE CLOSED - If all the above status are met, go to step 15.
- If one of the above status is not met, continue with next step.
- Perform wiring check between the crossfeed SOV (L34P1) and FMQGC (A47AP1).
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Check for 28 VDC at crossfeed SOV (L34P1).
- If voltage is not there, go to step 7.
- If voltage is there, continue with next step.
- Replace the crossfeed SOV actuator (L34P1).
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the crossfeed SOV (L34P1).
- If system checks are good, do close out.
- If fault remains, go to step 15.
- Check for 28 VDC at SPDA 2 (A14P1).
- If voltage is not there, go to step 9.
- If voltage is there, continue with next step.
- Perform a wiring check between SPDA 2 (A14P1) and the crossfeed SOV (L34P1).
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Check for ground at EMS CDU (A91P2) (A94P2).
- If ground is there, go to step 14.
- If ground is not there, continue with next step.
NOTE: A ground is sent to both EMS CDU when the XFEED SOV PBA is set to open (pushed in).
- Perform wiring check between ground stud (GS852) and FUEL control panel (AP5P1).
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Perform wiring check between FUEL control panel (AP5P1), XFEED SOV PBA (SDS3) and EMS CDU (A91P2) (A94P2).
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace the XFEED SOV PBA (SDS3).
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace the FUEL control panel (AP5).
- If system checks are good, do close out.
- If fault remains, go to step 15.
- Swap the SPDA 2 with SPDA 3.
- If system checks are good, replace SPDA 2 and do close out.
- If fault remains, continue with next step.
- Replace FMQGC.
- Do close out.