Message Overview:
Fault Message:
HYD EDP 1A FAIL
Fault Code:
0000H1AF
Associated CAS:
| Reporting LRU: | Data Acquisition Unit (DAU) 2 |
| System Description: | 29-30-00 |
| Schematic Diagram: | 29-12-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 29-00-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Data Acquisition Unit (DAU) 2 is reporting the Engine Driven Pump 1A at a pressure less than 2400 psi with the left engine running.
Possible Causes:
- Engine Driven Pump (EDP) 1A Pressure Switch (S34)
- Data Acquisition Unit (DAU) 2 (A18)
- Hydraulic Pressure Switch 1A
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Quantity Check of the Hydraulic Fluid in the No. 1 and No. 2 Hydraulic Systems | AMM 12-12-00-610-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Engine-Driven Hydraulic Pumps | AMM 29-12-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Engine-Driven Hydraulic Pumps | AMM 29-12-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Operational Test of the Engine-Driven Hydraulic Pumps | AMM 29-12-01-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Firewall Hydraulic Shutoff-Valves | AMM 29-12-33-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Firewall Hydraulic Shutoff-Valves | AMM 29-12-33-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Operational Test of the Firewall Hydraulic Shutoff-Valves | AMM 29-12-33-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Hydraulic Pressure Switches | AMM 29-31-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Hydraulic Pressure Switches | AMM 29-31-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Carry out a quantity check of the Hydraulic System 1.
- Verify that the left Engine Firewall Hydraulic Shutoff Valve is physically fully open.
- If the left Engine Firewall Hydraulic Shutoff Valve is not fully open, perform the operational test of the left Engine Firewall Hydraulic Shutoff Valve and replace if necessary.
- If the left Engine Firewall Hydraulic Shutoff Valve is fully open, continue with next step.
- Start the left Engine and check Hydraulic System 1 Pressure.
- If the pressure is low, replace the EDP 1 and do close out.
- If the pressure is good, continue with next step.
- With the engines running, disconnect the EDP 1A Pressure Switch connector S34P1 and install a jumper between S34P1-A and S34P1-B.
- If the message goes away, replace the pressure switch and do close out.
- If the message is still shown, remove jumper and install connector S34P1 and continue with next step.
- Swap DAU 2 with DAU 3.
- If system checks are good, replace DAU 2 and do close out.
- If fault remains, continue with next step.
- Perform a wiring check between the EDP 1A Pressure Switch and the DAU 2.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Do close out.