Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

07/22/19

Message Overview:

Fault Message:

AOA1 HEATER / WRG

Fault Code:

3030104HBM

Associated CAS:

L AOA HEAT FAIL
(Caution)

Reporting LRU: Heater/Brake-Temperature Monitoring Unit (HBMU) 1
System Description: 30-31-00
Schematic Diagram: 30-31-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 30-31-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

The Angle-of-Attack (AOA) 1 Heater circuit has been detected opened by Heater/Brake-Temperature Monitoring Unit (HBMU) 1.

Possible Causes:

  • Angle-of-Attack (AOA) 1 Heater
  • Heater/Brake-Temperature Monitoring Unit (HBMU) 1 (A121)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Angle-of-Attack Sensor AMM 27-32-09-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Angle-of-Attack Sensor AMM 27-32-09-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Heater/Brake-Temperature Monitoring Unit (HBMU) AMM 30-31-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Heater/Brake-Temperature Monitoring Unit (HBMU) AMM 30-31-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Perform wiring checks between HBMU 1 and AOA 1 Vane & Case heaters.

    1. If wiring checks are not good, repair defective wiring as required and do close out.
    2. If wiring checks are good, continue with next step.

  2. Measure the resistance of AOA 1 Vane & Case heaters.
    AOA vane heater= 30 +/-10 ohms
    AOA case heater =30 +/-12 ohms

    1. If resistance is within range, go to step 4.
    2. If resistance is out of range, continue with next step.

  3. Replace AOA 1 Heater.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  4. Replace HBMU 1.
  5. Do close out.