04/06/21
Message Overview:
Message Name:
PITOT-STATIC2 HEATER / WRG
Message Code:
3031104HBM
Associated CAS:
| Reporting LRU: | Heater/Brake Temperature Monitor Unit (HMBU) 2 |
| System Description: | 30-31-00 |
| Schematic Diagram: | 30-31-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 30-31-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
The PITOT-STATIC2 Probe Heater(s) circuit has been detected opened by Heater/Brake Temperature Monitor Unit (HBMU) 2.
Possible Causes:
- Pitot/Static Probe 2 Heater (MT152)
- Heater/Brake Temperature Monitor Unit (HMBU) 2 (A93)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-45-0065 - CAIMS Nuisance Fault Messages
Forum Articles/Infoservice/Newsletter: None
Notice To Operators (NTO): None
Flight Operation Notifications Manual (FONM): None
Quick Links:
| Removal of the Heater/Brake-Temperature Monitoring Unit (HBMU) | AMM 30-31-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Heater/Brake-Temperature Monitoring Unit (HBMU) | AMM 30-31-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Pitot-Static Probes | AMM 34-11-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Pitot-Static Probes | AMM 34-11-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Perform wiring checks between HBMU2 (A93P1) and Pitot Static Probe 2 Heater (MT152P1). Repair as required.
HBMU2 to Pitot/Static Probe 2 From: To: Expected Result: Actual Result: HBMU 2 A93P1-K Pitot/Static Probe 2 MT152P1-1 0 Ω Chassis Ground Pitot/Static Probe 2 MT152P1-2 0 Ω - If system checks are good, do close out.
- If fault remains, continue with next step.
- Measure the resistance of Pitot Static Probe 2 Heater.
Pitot/Static Probe 2 Head & Base Heaters From: To: Expected Result: Actual Result: Pitot/Static Probe 2 Head Heater MT152P1-1 Pitot/Static Probe 2 Head Heater MT152P1-2 20 Ω ±10 Ω @ 68°F [20°C] Pitot/Static Probe 2 Base Heater MT152P2-1 Pitot/Static Probe 2 Base Heater MT152P2-2 ≈ 210 Ω @ 68°F [20°C] PS2 probe head heater should be 20 Ω ±10 Ω at 68°F [20°C]
PS2 probe base heater should be 210 Ω approximately- If resistance within range, go to step 4.
- If resistance out of range, continue with next step.
- Replace Pitot Static Probe 2.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Interchange HBMUs. Replace if necessary.
- Do close out.