07/24/19
Message Overview:
Fault Message:
POT1LO/WRG/DAU 1
Fault Code:
3141014DAU
Associated CAS:
| Reporting LRU: | Data Acquisition Unit (DAU) 1 |
| System Description: | 27-22-00 31-40-00 |
| Schematic Diagram: | 27-20-00 [ Global Express ] [ G5000 ] [ Global XRS ] 31-42-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-20-01 [ Global Express ] [ G5000 ] [ Global XRS ] 31-42-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Data Acquisition Unit (DAU) 1 senses that the position analog signal from the Rudder Trim Actuator is out of range.
Possible Causes:
- Rudder Trim Actuator (B40)
- Data Acquisition Unit (DAU) 1 (A17)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Operational Test of the Rudder Trim System | AMM 27-22-00-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Rudder Trim Actuator | AMM 27-22-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Rudder Trim Actuator | AMM 27-22-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Operational Test of the Data Acquisition System | AMM 31-42-00-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Stored Faults | AMM 45-45-00-970-803 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Access Panel for the Rudder Trim Actuator (345AR) | AMM 55-30-13-000-806 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Access Panel for the Rudder Trim Actuator (345AR) | AMM 55-30-13-400-806 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Safety Precautions - Maintenance Practices - ALL | SPM 20-00-01-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Remove the DAU 1 to get access to the connector A17AP1 and Head-Up Display (HUD) Computer to get access to the connector B40P1. Perform a continuity check as follows:
From To Result A17AP1-D4 B40P1-D - If there is no continuity, repair or replace defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Perform a continuity check as follows:
From To Result A17AP1-D4 Ground - If there is no continuity, repair or replace defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Swap DAU 1 with DAU 3. Is the fault still present?
- If NO, do close out.
- If YES, continue with next step.
- Replace the Rudder Trim Actuator.
- Do close out.