08/01/19
Message Overview:
Fault Message:
RVT 2/WRG/DAU 3
Fault Code:
3146041DAU
Associated CAS:
| Reporting LRU: | Data Acquisition Unit (DAU) 3 |
| System Description: | 27-10-00 31-40-00 |
| Schematic Diagram: | 27-10-00 [ Global Express ] [ G5000 ] [ Global XRS ] 31-42-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 27-10-01 [ Global Express ] [ G5000 ] [ Global XRS ] 31-42-03 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Data Acquisition Unit (DAU 3) senses that the Position Transducer from the Left Aileron on CH B is out of range.
Possible Causes:
- Left Aileron Position Transducer (MT61)
- Data Acquisition Unit (DAU) 3 (A30)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Aileron Position Transducers | AMM 27-11-21-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Aileron Position Transducers | AMM 27-11-21-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Data Acquisition Units (DAU) | AMM 31-42-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Data Acquisition Units (DAU) | AMM 31-42-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Stored Faults | AMM 45-45-00-970-803 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Safety Precautions - Maintenance Practices - ALL | SPM 20-00-01-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Remove the DAU 3 to get access to the connector A30BP1 and left aileron position transducer to get access to the connector MT61P1. Perform a continuity check as follows:
From To Result A30BP1-D5 MT61P1-8 A30BP1-E5 MT61P1-7 - If there is no continuity, repair or replace defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Perform a continuity check as follows:
From To Result A30BP1-D5 Ground A30BP1-E5 Ground - If there is continuity, repair or replace defective wiring as required and do close out.
- If there is no continuity, continue with next step.
- Swap DAU 3 with DAU 1. Is the fault still present?
- If NO, replace DAU 3 and do close out.
- If YES, continue with next step.
- Replace the left aileron position transducer.
- Do close out.