08/08/19
Message Overview:
Fault Message:
LG ECU CHAN B LOSS OF DC & BATT PWR
Fault Code:
3230270EL
Associated CAS:
| Reporting LRU: | Landing Gear Electronic Control Unit (LG ECU) |
| System Description: | 32-31-00 |
| Schematic Diagram: | 32-31-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 32-31-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Landing Gear Electronic Control Unit (LG ECU) has detected a lost of Power on Channel B (28 V BATT (CHAN B) and 28 VDC2).
Possible Causes:
- Secondary Power Distribution Assembly (SPDA) 2 (A14)
- Landing Gear Electronic Control Unit (LG ECU) (A52)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Secondary-Power Distribution Assemblies | AMM 24-62-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Secondary-Power Distribution Assemblies | AMM 24-62-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Landing-Gear Electronic Control-Unit (LG ECU) |
AMM 32-31-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Landing-Gear Electronic Control-Unit (LG ECU) |
AMM 32-31-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Operational Test of the Landing-Gear Electronic Control-Unit (LG ECU) |
AMM 32-31-09-710-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Make sure circuit breakers are IN. Check EMSCDU for the following circuit breakers are in Gear CTL B PWR 2 and Gear CTL B PWR 1.
- Confirm voltage is present by looking in CAIMS System Diag. Select ATA 24 then select SEC PWR DIST. ASSY. 2A Then select LRU Test. You can now locate the label by the Index or go directly to Label 010-017 and select load which will give you Label 010 Load 1-SPDA 2A, confirm page and will bring you to load 2 all values will show in red to select is made and voltage will show voltage or will show absent.
- If voltage is good, go to step 4.
- If voltage is absent, continue with next step.
- Swap SPDA 2 with SPDA 3.
- If system checks are good, replace SPDA 2 and do close out.
- If fault remains, continue with next step.
- Re-seat LGECU.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace LGECU.
- Do close out.