08/09/19
Message Overview:
Fault Message:
LG ECU CHAN A LOSS OF DC & BATT PWR
Fault Code:
3231223EL
Associated CAS:
| Reporting LRU: | Landing Gear Electronic Control Unit (LG ECU) |
| System Description: | 32-31-00 |
| Schematic Diagram: | 32-31-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 32-31-05 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
This message shows when there is no power supplied to Landing Gear Electronic Control Unit (LG ECU) channel A.
Possible Causes:
- Landing Gear Electronic Control Unit (LG ECU) (A52)
- Secondary Power Distribution Assembly (SPDA) 3 (A15)
- Secondary Power Distribution Assembly (SPDA) 4 (A16)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Connect Electrical Power to the Aircraft | AMM 24-00-00-861-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Remove the Electrical Power from the Aircraft | AMM 24-00-00-861-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Secondary-Power Distribution Assemblies | AMM 24-62-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Secondary-Power Distribution Assemblies | AMM 24-62-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Landing-Gear Electronic Control-Unit (LG ECU) | AMM 32-31-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Landing-Gear Electronic Control-Unit (LG ECU) | AMM 32-31-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Make sure circuit breakers are IN and Check in the EMS CDU for the following circuit breakers are in Gear CTL A PWR 2 and Gear CTL A PWR 1.
- If fault indication is gone, do close out.
- If fault remains, continue with next step.
- Disconnect, inspect and reconnect the following connectors A15P1 of the SPDA 3, A16P1 of the SPDA 4 and the connector A52CP1 of the LGECU.
- If fault indication is gone, do close out.
- If fault remains, continue with next step.
- Re-seat the LGECU.
- If fault indication is gone, do close out.
- If fault remains, continue with next step.
- Perform wiring checks between the LGECU connector A52CP1, SPDA 3 connector A15P1 and SPDA 4 connector A16P1.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace LGECU.
- Do close out.