08/17/19
Message Overview:
Fault Message:
EVSHC INTERNAL (ARINC SELF TEST)
Fault Code:
3000117IN
Associated CAS:
| Reporting LRU: | Enhanced Vision System Heater Controller (EVSHC) |
| System Description: | 34-33-00 |
| Schematic Diagram: | 34-33-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 34-33-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Enhanced Vision System Heater Controller (EVSHC) has internal failure.
Possible Causes:
- Enhanced Vision System Heater Controller (EVSHC) (A315)
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-34-0460 - Enhanced Vision System Heater Controller (EVSHC) nuisance fault on power-up
- AW700-45-0065 - CAIMS Nuisance Fault Messages
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Enhanced Vision System (EVS) Heater Controller |
AMM 34-33-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Enhanced Vision System (EVS) Heater Controller |
AMM 34-33-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- This could be a nuisance fault make sure to comply with the AW above in the Troubleshooting Tips area.
- Replace EVSHC.
- Do close out.