background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults By CAIMS By Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

09/05/19

Message Overview:

Fault Message:

INTERFACE - SWC 1 BUS FAULT

Fault Code:

3440106AE

Associated CAS:

GPWS SYSTEMS FAIL
(Advisory)

WINDSHEAR FAIL
(Advisory)

Reporting LRU: Enhanced Ground-Proximity Warning System (EGPWS)
System Description: 34-42-00
Schematic Diagram: 34-42-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 27-32-04 [ Global Express ]  [ G5000 ]  [ Global XRS ]
34-42-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

Loss of communication on ARINC 429 bus from Stall Protection Computer (SPC) CH A is detected by Enhanced Ground-Proximity Warning System (EGPWS) Computer.

Possible Causes:

  • Stall Protection Computer (SPC) (A40)
  • Enhanced Ground-Proximity Warning System (EGPWS) Computer (A64)
  • Junction Box (JB) 5
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter:

Quick Links:

Removal of the Stall Protection Computer AMM 27-32-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Stall Protection Computer AMM 27-32-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Enhanced Ground-Proximity
Warning System (EGPWS) Computer
AMM 34-42-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Enhanced Ground-Proximity
Warning System (EGPWS) Computer
AMM 34-42-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Consult EGPWS - NFF reduction before performing the troubleshooting.
  2. Perform wiring checks between SPC CHA, JB5 and EGPWS Computer.

    1. If wiring checks are not good, repair defective wiring as required and do close out.
    2. If wiring checks are good, continue with next step.
      NOTE: Remove all interface components for short circuit checks.

  3. Replace EGPWS Computer.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  4. Replace SPC.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  5. Replace JB5.
  6. Do close out.