background
x
loader
Troubleshooting
arrow By ATA By Message Color By Observed Faults By CAIMS By Tips

Select color for CAS message that you wish to troubleshoot

(WARNING)
RED MESSAGE
(CAUTION)
AMBER MESSAGE
(ADVISORY)
CYAN MESSAGE
(STATUS)
WHITE MESSAGE
Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

09/10/19

Message Overview:

Fault Message:

BMC1 [NO DATA] /DAU1 [CH A] /WRG

Fault Code:

3615324BMC

Associated CAS:

L BLEED SYS FAIL
(Caution)

L BLEED FAULT
(Advisory)

Reporting LRU: Bleed Management Controller (BMC)
System Description: 36-11-00
Schematic Diagram: 31-42-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 31-42-05 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

The Bleed Management Controller (BMC) 1 does not receive data from Channel A of Data Acquisition Unit (DAU) 1. Inhibited during Take-Off and Landing.

Possible Causes:

  • Bleed Management Controller (BMC) 1 (A69)
  • Data Acquisition Unit (DAU) 1 (A17)
  • Junction Box (JB3)/PCB2
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

  • AW700-36-0365 - Bleed Management Controller - Data Gathering to Reduce No Fault Found (NFF) rate

Forum Articles/Infoservice/Newsletter:

  • Forum Article 2011-VOL 8 issue 23 - Bleed Management Controller (BMC) Top 10 No Fault Found (NFF) vs. Reliability Improvement Modification Program (RIMP) implementation
  • Questionnaire for replacing the BMC. Follow instructions using this (Fill out form)

NOTE: Always verify you are working with the current document revision. Access the CIC website to ensure the latest document revision.

  • Test Points on Junction Box for troubleshooting reference

Quick Links:

Removal of the Junction Box JB3 AMM 24-00-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Junction Box JB3 AMM 24-00-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Junction Box JB3 Circuit-Cards AMM 24-00-02-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Junction Box JB3 Circuit-Cards AMM 24-00-02-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Data Acquisition Units (DAU) AMM 31-42-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Data Acquisition Units (DAU) AMM 31-42-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Bleed Management Controller AMM 36-11-33-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Bleed Management Controller AMM 36-11-33-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Swap BMC 1 with BMC 2.

    1. If system checks are good, replace BMC 1 and do close out.
    2. If fault remains, continue with next step.

  2. Swap DAU 1 with DAU 3, if other units connected to the same ARINC GP Bus do not receive data.

    1. If system checks are good, replace DAU 1 and do close out.
    2. If fault remains, continue with next step.

  3. Perform wiring checks between BMC 1, JB3 and DAU 1.

    1. If wiring checks are not good, repair defective wiring as required and do close out.
    2. If wiring checks are good, continue with next step.
      NOTE: Remove all interface components for short test.

  4. Replace JB3/PCB2.
  5. Do close out.
Registered and/or unregistered trademarks of Bombardier Inc. or its subsidiaries. © 2015 Bombardier Inc. All rights reserved.