Message Overview:
Fault Message:
RIGHT BLEED AIR DUCTS RUPTURE
Fault Code:
3616417BMC
Associated CAS:
| Reporting LRU: | Bleed Management Controller (BMC) 2 |
| System Description: | 36-11-00 |
| Schematic Diagram: | 36-11-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 36-11-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Bleed Management Controller (BMC) 2 senses that the opposite bleed pressure is higher by 10 Pound per Square Inch (gage) (PSIG) when the Cross-Bleed Valve is fully open and the Left Bleed-Pressure Regulating-and-Shutoff Valve is closed. Inhibited during Take-off and Landing.
Possible Causes:
- Bleed Management Controller (BMC) 2 (A70)
- Right Bleed Pressure Transducer (BPT) (MT112)
- Right Bleed Air Duct
- Junction Box (JB4)/PCB2
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-36-0365 - Bleed management controller - Data Gathering to reduce No Fault Found (NFF) rate
Forum Articles/Infoservice/Newsletter:
- Forum Article 2011-VOL 8 issue 23 - Bleed Management Controller (BMC) Top 10 No Fault Found (NFF) vs. Reliability Improvement Modification Program (RIMP) implementation
- Questionnaire for replacing the BMC. Follow instructions using this (Fill out form)
NOTE: Before removing JB4, replace PCB2 Circuit Card if available.
NOTE: Always verify you are working with the current document revision. Access the CIC website to ensure the latest document revision.
Quick Links:
| Removal of the Junction Box JB4 | AMM 24-00-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Junction Box JB4 | AMM 24-00-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Junction Box JB4 Circuit-Cards | AMM 24-00-06-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Junction Box JB4 Circuit-Cards | AMM 24-00-06-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Leak Test of the Bleed Air System | AMM 36-11-00-790-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Bleed Pressure Transducer | AMM 36-11-25-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Bleed Pressure Transducer | AMM 36-11-25-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Bleed Management Controller | AMM 36-11-33-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Bleed Management Controller | AMM 36-11-33-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Bleed Air Ducts | AMM 36-11-45-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Bleed Air Ducts | AMM 36-11-45-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Inspect RIGHT bleed ducts for duct integrity and signs of rupture.
- If faults are found, adjust the couplings, remove and reinstall or replace the faulty components as required.
- If there are no faults, continue with next step.
- Perform the leak test of bleed air system.
- If system checks are good, then go to step 6.
- If fault remains, continue with next step.
- Swap Right Bleed pressure transducer (BPT) with Left Bleed pressure transducer (BPT) and inspect BPT sense line.
- If system checks are good, replace right BPT and do close out.
- If fault remains, continue with next step.
- Swap Bleed Management Computer (BMC) 2 with Bleed Management Computer (BMC) 1.
- If system checks are good, replace BMC 2 and do close out.
- If fault remains, continue with next step.
- Perform wiring checks between BPT to JB4/PCB2.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Perform wiring checks between BPT to BMC 2.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Perform continuity check of JB4/PCB2.
- If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Replace JB4/PCB2.
- Do close out.