09/12/19
Message Overview:
Fault Message:
R OUTBD/INBD WAIT SNSR INSTALLATION
Fault Code:
3616419BMC
Associated CAS:
| Reporting LRU: | Bleed Management Controller (BMC) 2 |
| System Description: | 30-12-00 |
| Schematic Diagram: | 30-11-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 30-11-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Message Description:
A Right Wing Leading-Edge Over-Temperature condition is detected by the Outboard Wing Anti-Ice Temperature Sensor (WAITS) (Temperature > 133 °C).
Possible Causes:
- Right Inboard Anti-Icing Temperature Sensor (E41)
- Right Outboard Anti-Icing Temperature Sensor (E40)
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Anti-Icing Temperature Sensors | AMM 30-11-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Anti-Icing Temperature Sensors | AMM 30-11-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Anti-Icing Temperature Sensors | AIPC 30-11-05 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Verify installation of right OUTBD WAITS as per AMM and reinstall if it is out of tolerance.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Verify installation of right INBD WAITS as per AMM and reinstall if it is out of tolerance.
- Do close out.