09/12/19
Message Overview:
Fault Message:
RIGHT INTMD PRESS XDCR /WRG /SENS L
Fault Code:
3616428BMC
Associated CAS:
| Reporting LRU: | Bleed Management Controller (BMC) 2 |
| System Description: | 36-11-00 |
| Schematic Diagram: | 36-11-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 71-50-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Intermediate Pressure Transducer (IPPT) 2 has been detected faulty by Bleed Management Controller (BMC) 2. Inhibited during Take-Off and Landing.
Possible Causes:
- Right Intermediate Pressure Transducer (IPPT)
- Secondary Power Distribution Assembly (SPDA) 3 (A15)
- Bleed Management Controller (BMC) 2 (A70)
- Junction Box (JB4)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin:
- AW700-36-0365 - Bleed management controller - Data Gathering to reduce No Fault Found (NFF) rate
Forum Articles/Infoservice/Newsletter:
- Forum Article 2011-VOL 8 issue 23 - Bleed Management Controller (BMC) Top 10 No Fault Found (NFF) vs. Reliability Improvement Modification Program (RIMP) implementation
- Questionnaire for replacing the BMC. Follow instructions using this (Fill out form)
NOTE: Always verify you are working with the current document revision. Access the CIC website to ensure the latest document revision.
NOTE: Before removing JB4, replace PCB2 Circuit Card if availble. - IPPT value is available in CAIMS.
- JB test points are available.


Quick Links:
| Removal of the Junction Box JB4 | AMM 24-00-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Junction Box JB4 | AMM 24-00-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Secondary-Power Distribution Assemblies | AMM 24-62-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Secondary-Power Distribution Assemblies | AMM 24-62-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Bleed Management Controller | AMM 36-11-33-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Bleed Management Controller | AMM 36-11-33-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Intermediate-Pressure Transducer | AMM 36-11-37-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Intermediate-Pressure Transducer | AMM 36-11-37-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
Bleed Pressure Transducer is affected:
- Swap SPDA 3 with SPDA 2.
- If system checks are good, replace SPDA 3 and do close out.
- If fault remains, continue with next step.
- Perform wiring checks between JB4 and SPDA 3.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace JB4.
- Do close out.
Bleed Pressure Transducer is not affected:
- Swap IPPT 2 with IPTT 1.
- If system checks are good, replace IPPT 2 and do close out.
- If fault remains, continue with next step.
- Swap BMC 2 with BMC 1.
- If system checks are good, replace BMC 2 and do close out.
- If fault remains, continue with next step.
- Perform wiring checks between JB4 and BMC 2.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Perform wiring checks between IPPT 2 and BMC 2.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Perform wiring checks between IPPT 2 and JB4.
- If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Replace JB4.
- Do close out.