Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

09/12/19

Message Overview:

Fault Message:

RIGHT PRESS XDCR POWER SUPPLY /WRG

Fault Code:

3616429BMC

Associated CAS:

R BLEED FAULT
(Advisory)

Reporting LRU: Bleed Management Controller (BMC) 2
System Description: 36-11-00
Schematic Diagram: 36-11-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 71-50-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

Bleed Management Controller (BMC) 2 senses that the Secondary Power Distribution Assembly (SPDA) 3 does not supply 28 VDC from its sensors output. Inhibited during Take-Off and Landing.

Possible Causes:

  • Secondary Power Distribution Assembly (SPDA) 3 (A15)
  • Bleed Management Controller (BMC) 2 (A70)
  • Junction Box (JB3)
  • Right Bleed Pressure Transducer (MT112)
  • Right Intermediate Pressure Transducer (IPPT)
  • Right Cowl Anti-Icing Pressure Transducer (CAIPT)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

  • AW700-36-0365 - Bleed management controller - Data Gathering to reduce No Fault Found (NFF) rate

Forum Articles/Infoservice/Newsletter:

  • Forum Article 2011-VOL 8 issue 23 - Bleed Management Controller (BMC) Top 10 No Fault Found (NFF) vs. Reliability Improvement Modification Program (RIMP) implementation
  • Questionnaire for replacing the BMC. Follow instructions using this (Fill out form)
    NOTE: Before removing JB4, replace PCB2 Circuit Card if availble.
    NOTE: Always verify you are working with the current document revision. Access the CIC website to ensure the latest document revision.

Quick Links:

Removal of the Junction Box JB3 AMM 24-00-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Junction Box JB3 AMM 24-00-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Secondary-Power Distribution Assemblies AMM 24-62-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Secondary-Power Distribution Assemblies AMM 24-62-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Cowl Anti-Icing Valve AMM 30-21-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Cowl Anti-Icing Valve AMM 30-21-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Bleed Pressure Transducer AMM 36-11-25-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Bleed Pressure Transducer AMM 36-11-25-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Bleed Management Controller AMM 36-11-33-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Bleed Management Controller AMM 36-11-33-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Intermediate-Pressure Transducer AMM 36-11-37-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Intermediate-Pressure Transducer AMM 36-11-37-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Swap SPDA 3 with SPDA 2.

    1. If system checks are good, replace SPDA 3 and do close out.
    2. If fault remains, continue with next step.

  2. Perform wiring checks between SPDA 3, JB3, R BPT, R IPPT, R CAIPT and BMC 2.

    1. If wiring checks are not good, repair defective wiring as required and do close out.
    2. If wiring checks are good, continue with next step.
      NOTE: Remove all interface components for short test.

  3. Swap Right BPT with Left BPT.

    1. If system checks are good, replace Right BPT and do close out.
    2. If fault remains, continue with next step.

  4. Swap Right IPPT with Left IPPT.

    1. If system checks are good, replace Right IPPT and do close out.
    2. If fault remains, continue with next step.

  5. Swap BMC 2 with BMC 1.

    1. If system checks are good, replace BMC 2 and do close out.
    2. If fault remains, continue with next step.

  6. Replace cowl anti-ice valve.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  7. Replace JB3.
  8. Do close out.