Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

09/16/19

Message Overview:

Fault Message:

APU SHUT DOWN - INLET DOOR NOT OPEN

Fault Code:

4960122APU

Associated CAS:

APU SHUTDOWN
(Advisory)

Reporting LRU: Full-Authority Digital Engine-Controller (FADEC)
System Description: 49-60-00
Schematic Diagram: 49-61-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 49-61-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

The Full-Authority Digital Engine-Controller (FADEC) commanded an Auxiliary Power Unit (APU) shut down because the inlet door closed during operation.

Possible Causes:

  • Door Actuator (A199)
  • Inlet Door Rotary Transducer (MT5)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin: None

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Linear Actuator AMM 49-14-05-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Linear Actuator AMM 49-14-05-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Full-Authority Digital Engine-Controller (FADEC) AMM 49-61-01-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Full-Authority Digital Engine-Controller (FADEC) AMM 49-61-01-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Open the Auxiliary Power Unit (APU) Access Doors (321BB) AMM 52-43-00-010-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Close the Auxiliary Power Unit (APU) Access Doors (321BB) AMM 52-43-00-410-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wire Repair - Maintenance Practices - ALL SPM 20-12-10-02 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. On the CAIMS PMAT, get access to the active faults.

    1. If the fault message FADEC CONTROLLER shows on the CAIMS PMAT, go to step 8.
    2. If the fault message not shows, continue with next step.

  2. On the CAIMS PMAT, get access to the active faults.

    1. If the APU SHUTDOWN (Advisory) still shows on the EICAS primary display, go to step 4.
    2. If any of the fault messages that follow show on the CAIMS PMAT, continue with next step.

  3. Troubleshoot fault message that follows:

    1. OPEN CKT−INL DOOR RTRY XDCR/EXC
    2. OPEN CKT−INL DOOR XDCR/SEC VA WRG
    3. OPEN CKT−INL DOOR XDCR/SEC VB WRG
    4. SHORT−INL DOOR RTRY XDCR/SEC VA WRG
    5. SHORT−INL DOOR RTRY XDCR/SEC VB WRG

  4. Examine the linear actuator (A199) receptacle for contamination and damage.

    1. If there is contamination or damage, repair or replace as required and do close out.
    2. If there is no contamination or damage, continue with next step.

  5. Perform a resistance check on actuator connector as follows:

    From To Expected Result Result
    A199P1-A Ground >1 megohm
    A199P1-C Ground >1 megohm
    A199P1-D Ground >1 megohm

    1. If resistance checks good, go to step 9.
    2. If resistance checks not good, continue with next step.

  6. Perform a resistance check on connector as follows:

    From To Expected Result Result
    P803-E Ground >1 megohm
    P803-F Ground >1 megohm

    1. If resistance checks not good, repair or replace defective wiring as required and do close out.
    2. If resistance checks good, continue with next step.

  7. Perform a resistance check on connector as follows:

    From To Expected Result Result
    J803-E Ground >1 megohm
    J803-F Ground >1 megohm

    1. If resistance checks not good, repair or replace defective wiring as required and do close out.
    2. If resistance checks good, continue with next step.

  8. Replace APU FADEC.

    1. If system checks are good, do close out.
    2. If fault remains, continue with next step.

  9. Replace Linear Actuator (A199).
  10. Do close out.