Message Overview:
Fault Message:
APU SHUT DOWN - INLET DOOR NOT OPEN
Fault Code:
4960122APU
Associated CAS:
| Reporting LRU: | Full-Authority Digital Engine-Controller (FADEC) |
| System Description: | 49-60-00 |
| Schematic Diagram: | 49-61-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 49-61-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Full-Authority Digital Engine-Controller (FADEC) commanded an Auxiliary Power Unit (APU) shut down because the inlet door closed during operation.
Possible Causes:
- Door Actuator (A199)
- Inlet Door Rotary Transducer (MT5)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Removal of the Linear Actuator | AMM 49-14-05-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Linear Actuator | AMM 49-14-05-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Full-Authority Digital Engine-Controller (FADEC) | AMM 49-61-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Full-Authority Digital Engine-Controller (FADEC) | AMM 49-61-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Open the Auxiliary Power Unit (APU) Access Doors (321BB) | AMM 52-43-00-010-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Close the Auxiliary Power Unit (APU) Access Doors (321BB) | AMM 52-43-00-410-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- On the CAIMS PMAT, get access to the active faults.
- If the fault message FADEC CONTROLLER shows on the CAIMS PMAT, go to step 8.
- If the fault message not shows, continue with next step.
- On the CAIMS PMAT, get access to the active faults.
- If the APU SHUTDOWN (Advisory) still shows on the EICAS primary display, go to step 4.
- If any of the fault messages that follow show on the CAIMS PMAT, continue with next step.
- Troubleshoot fault message that follows:
- OPEN CKT−INL DOOR RTRY XDCR/EXC
- OPEN CKT−INL DOOR XDCR/SEC VA WRG
- OPEN CKT−INL DOOR XDCR/SEC VB WRG
- SHORT−INL DOOR RTRY XDCR/SEC VA WRG
- SHORT−INL DOOR RTRY XDCR/SEC VB WRG
- Examine the linear actuator (A199) receptacle for contamination and damage.
- If there is contamination or damage, repair or replace as required and do close out.
- If there is no contamination or damage, continue with next step.
- Perform a resistance check on actuator connector as follows:
From To Expected Result Result A199P1-A Ground >1 megohm A199P1-C Ground >1 megohm A199P1-D Ground >1 megohm - If resistance checks good, go to step 9.
- If resistance checks not good, continue with next step.
- Perform a resistance check on connector as follows:
From To Expected Result Result P803-E Ground >1 megohm P803-F Ground >1 megohm - If resistance checks not good, repair or replace defective wiring as required and do close out.
- If resistance checks good, continue with next step.
- Perform a resistance check on connector as follows:
From To Expected Result Result J803-E Ground >1 megohm J803-F Ground >1 megohm - If resistance checks not good, repair or replace defective wiring as required and do close out.
- If resistance checks good, continue with next step.
- Replace APU FADEC.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Replace Linear Actuator (A199).
- Do close out.