08/29/19
Message Overview:
Fault Message:
SHORT-INL DOOR RTRY XDCR/SEC VB WRG
Fault Code:
4960318APU
Associated CAS:
| Reporting LRU: | Full-Authority Digital Engine-Controller (FADEC) |
| System Description: | 49-10-00 |
| Schematic Diagram: | 49-61-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 49-12-01 [ Global Express ] [ G5000 ] [ Global XRS ] 49-61-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
The Full-Authority Digital Engine-Controller (FADEC) commanded an Auxiliary Power Unit (APU) shut down because the FADEC received a signal from the Inlet-Door Rotary Transducer that was out of the expected range.
Possible Causes:
- Inlet-Door Rotary Transducer (MT5)
- Full-Authority Digital Engine-Controller (FADEC) (A108)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Quick Links:
| Connect Electrical Power to the Aircraft | AMM 24-00-00-861-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Remove the Electrical Power from the Aircraft | AMM 24-00-00-861-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Opening of Non-Thermal Circuit Breakers | AMM 24-00-00-863-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Closing of Non-Thermal Circuit Breakers | AMM 24-00-00-863-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Electrical/Electronic Safety Precautions | AMM 24-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Access to Active Faults | AMM 45-45-00-970-802 [ Global Express ] [ G5000 ] [ Global XRS ] |
| APU Safety Precautions | AMM 49-00-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Inlet-Door Rotary Transducer | AMM 49-14-09-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Inlet-Door Rotary Transducer | AMM 49-14-09-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Full-Authority Digital Engine- Controller (FADEC) |
AMM 49-61-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Full-Authority Digital Engine- Controller (FADEC) |
AMM 49-61-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Open the Auxiliary Power Unit (APU) Access Doors (321BB) |
AMM 52-43-00-010-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Close the Auxiliary Power Unit (APU) Access Doors (321BB) |
AMM 52-43-00-410-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the External Avionics-Compartment Access- Panel (140BB) |
AMM 52-45-11-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the External Avionics-Compartment Access- Panel (140BB) |
AMM 52-45-11-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Safety Precautions - Maintenance Practices - ALL | SPM 20-00-01-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Check if the fault message 'FADEC CONTROLLER' is displayed on the CAIMS PMAT.
- If NO, go to step 3.
- If YES, replace the FADEC and continue with next step.
- Check if the following CAS messages are displayed on the EICAS primary display.
- If NO, do close out.
- If YES, continue with next step.
- Disconnect the P2 connector of the inlet-door rotary transducer (MT5) from the J804 connector. Check the P2 connector for contamination and damage.
- If there is a damage, go to step 12.
- If there is no damage, continue with next step.
- Perform a continuity check between the pins of the connector P2 as follows:
From To Expected Result Result MT5P2-1 MT5P2-6 <1000 ohms MT5P2-6 MT5P2-4 <1000 ohms MT5P2-2 MT5P2-3 <1000 ohms - If the resistance check is not as mentioned above, go to step 12.
- If the resistance check is as mentioned above, continue with next step.
- Perform a continuity check between each pins of the connector P2 and the grounded shell as follows:
From To Expected Result Result MT5P2-1 Ground >1 megaohm MT5P2-6 Ground >1 megaohm MT5P2-4 Ground >1 megaohm MT5P2-2 Ground >1 megaohm MT5P2-3 Ground >1 megaohm - If the resistance check is not as mentioned above, go to step 12.
- If the resistance check is as mentioned above, continue with next step.
- Disconnect the connector P803 at the APU firewall interface (FS1046 LHS). Perform a continuity check between the pins of the connectors as follows:
From To Expected Result Result P803-H J804-1 <1 ohm P803-J J804-6 <1 ohm P803-K J804-4 <1 ohm P803-A J804-2 <1 ohm P803-B J804-3 <1 ohm - If the resistance check is not as mentioned above, repair defective wiring as required and do close out.
- If the resistance check is as mentioned above, continue with next step.
- Perform a continuity check between each pins of the connector as follows:
From To Expected Result Result P803-H J803-J >1 megaohm P803-J J803-K >1 megaohm P803-A J803-B >1 megaohm - If the resistance check is not as mentioned above, repair defective wiring as required and do close out.
- If the resistance check is as mentioned above, continue with next step.
- Perform a continuity check between each pins and the grounded shell as follows:
From To Expected Result Result P803-H Ground >1 megaohm P803-K Ground >1 megaohm P803-A Ground >1 megaohm P803-B Ground >1 megaohm - If the resistance check is not as mentioned above, repair defective wiring as required and do close out.
- If the resistance check is as mentioned above, continue with next step.
- Disconnect the connector J803 at the APU firewall interface (FS1046 LHS) and Remove FADEC connector (A108BP1). Perform a continuity check between the pins of the connectors as follows:
From To Expected Result Result P803-H A108BP1-C8 <3 ohms P803-J A108BP1-B8 <3 ohms P803-K A108BP1-A8 <3 ohms P803-A A108BP1-A7 <3 ohms P803-B A108BP1-B7 <3 ohms - If the resistance check is not as mentioned above, repair defective wiring as required and do close out.
- If the resistance check is as mentioned above, continue with next step.
- Perform a continuity check between the pins of the connectors that follows:
From To Expected Result Result P803-H J803-J <1 ohm P803-J J803-K <1 ohm P803-A J803-B <1 ohm - If the resistance check is not as mentioned above, repair defective wiring as required and do close out.
- If the resistance check is as mentioned above, continue with next step.
- Perform a continuity check between each pin and the grounded shell as follows:
From To Expected Result Result P803-H Ground >1 megaohm P803-K Ground >1 megaohm P803-A Ground >1 megaohm P803-B Ground >1 megaohm - If the resistance check is not as mentioned above, repair defective wiring as required and do close out.
- If the resistance check is as mentioned above, continue with next step.
- Replace the Inlet Door Rotary Transducer (MT5).
- Do close out.