Message Overview:
Fault Message:
R TR LOWER L LOCK SW/WRG/P LOCK
Fault Code:
7325721RBR
Associated CAS:
| Reporting LRU: | Right Engine Electronic Controller (EEC) |
| System Description: | 78-30-00 |
| Schematic Diagram: | 78-34-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | 71-50-01 [ Global Express ] [ G5000 ] [ Global XRS ] |
Fault Description:
Right Engine Thrust Reverser (TR) Lower Door Left Stow Switch indicates that the door is not fully stowed when the TR are commanded stowed.
Possible Causes:
- Door Stow Switch
- Primary Lock Actuator
- Right Engine Electronic Controller (EEC)
- Associated Wiring
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
- TR Stow switch is also called the TR retracted switch.
Rolls-Royce NTO:
- NTO 066, Issue 4 - TRU Binding Primary Door Lock Mechanism
- NTO 135, Issue 1 - Issue of repeat Technical Variance 11595R (TR Stow Switch)
- Rolls-Royce SB-BR 700-78-101529
Quick Links:
| Opening of the Cowls | AMM 71-10-00-010-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Closing of the Cowls | AMM 71-10-00-410-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Thrust Reverser Safety Precautions | AMM 78-30-00-910-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Deactivation of the Thrust Reverser (for Maintenance) | AMM 78-30-00-040-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Activation of the Thrust Reverser (for Maintenance) | AMM 78-30-00-440-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Visual Check of the Thrust Reverser System | AMM 78-30-00-210-807 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Manual Opening of the Pivoting Doors | AMM 78-31-01-010-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Manual Closing of the Pivoting Doors | AMM 78-31-01-410-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Eng Electronic Controller (EEC) Mod 73-101559 |
EMM 73-21-01-000-801-B00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Eng Electronic Controller (EEC) Mod 73-101559 |
EMM 73-21-01-400-801-B001 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Exhaust Access Panels | EMM 78-00-00-010-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Exhaust Access Panels | EMM 78-00-00-410-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Rigging check of the Pivoting Doors | EMM 78-31-01-220-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Rigging of the Pivoting Doors | EMM 78-31-01-820-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Primary Lock Actuator and Mechanism | EMM 78-33-04-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Primary Lock Actuator and Mechanism | EMM 78-33-04-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Removal of the Door Retracted Switch | EMM 78-34-01-000-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Installation of the Door Retracted Switch | EMM 78-34-01-400-801 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wire Repair - Maintenance Practices - ALL | SPM 20-12-10-02 [ Global Express ] [ G5000 ] [ Global XRS ] |
Troubleshooting Recommendations:
- Check door rigging, including distortion, debris or damage around the TR door.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Check primary lock actuator and mechanism for sign of corrosion or binding.
- If system checks are good, do close out.
- If fault remains, continue with next step.
- Perform a continuity check on connector as follows. Shall have continuity when TR door is stowed.
From To Result P7004-1 P7004-2 P7012-1 P7012-2 - If there is no continuity, repair defective wiring as required and do close out.
- If there is continuity, continue with next step.
- Perform wiring checks between door stow switch and EEC.
- If wiring checks are not good, repair defective wiring as required and do close out.
- If wiring checks are good, continue with next step.
- Replace Right EEC.
- Do close out.