06/22/21
Message Overview:
Message Name:
Irregular Pressurization
| Identifier: | 213OBS001 |
| Effectivity: | All |
| System: | Air Conditioning |
| Associated CAS: | None |
| System Description: | 21-31-00 |
| Schematic Diagram: | 21-31-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | None |
Message Description:
The cabin-pressure control system does not operate correctly.
Possible Causes:
- Interface wiring (related to the disable command DSBL CMD) between CPC 1/CPC 2 And Outflow Valve 1/ Outflow Valve 2
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Notice To Operators (NTO): None
Flight Operation Notifications Manual (FONM): None
Quick Links:
None
Troubleshooting Recommendations:
- Perform the following CAIMS troubleshooting:
- [CPC1] OUTFLOW VLV #1 DSBL CMD /WRG (2137323ABG)
- [CPC1] OUTFLOW VLV #2 DSBL CMD /WRG (2137322ABG)
- [CPC2] OUTFLOW VLV #1 DSBL CMD /WRG (2138323ABG)
- [CPC2] OUTFLOW VLV #2 DSBL CMD /WRG (2138322ABG)
- Do close out.