06/22/21
Message Overview:
Message Name:
PACK TEMPERATURE SENSOR INDICATION ON PMAT IS OUT OF TOLERANCE COMPARED TO AMBIENT TEMPERATURE
| Identifier: | 215OBS013 |
| Effectivity: | All |
| System: | Air Conditioning |
| Associated CAS: | None |
| System Description: | 21-52-00 |
| Schematic Diagram: | 21-52-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | None |
Message Description:
ACSC receives an incorrect temperature signal from a pack temperature sensor.
Possible Causes:
- Left Pack Temperature Sensor (E26)
- Right Pack Temperature Sensor (E32)
- Interface wiring between Left Pack Temperature Sensor and Air-Conditioning System Controller (ACSC) 1
- Interface wiring between Right Pack Temperature Sensor and Air-Conditioning System Controller (ACSC) 2
- Air-Conditioning System Controller (ACSC) 1
- Air-Conditioning System Controller (ACSC) 2
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Notice To Operators (NTO): None
Flight Operation Notifications Manual (FONM): None
Quick Links:
None
Troubleshooting Recommendations:
- Perform the following CAIMS troubleshooting:
- [ACSC1-A] LH PACK TEMP SENS /WRG (2161423ECS)
- [ACSC1-B] LH PACK TEMP SENS /WRG (2162423ECS)
- [ACSC2-A] RH PACK TEMP SENS /WRG (2163423ECS)
- [ACSC2-B] RH PACK TEMP SENS /WRG (2164423ECS)
- Do close out.