06/22/21
Message Overview:
Message Name:
Pack Discharge Overheat
| Identifier: | 216OBS004 |
| Effectivity: | All |
| System: | Air Conditioning |
| System Description: | 21-60-00 |
| Schematic Diagram: | 21-60-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | None |
Message Description:
An overheat condition is detected at the outlet of the compressor stage of the LH/RH air cycle machine.
Possible Causes:
- Temperature Control Valve
- Pack Discharge Temperature Sensor
- Pack Temperature Sensor
- Mix Manifold Temperature Sensor
- Pack Inlet Temperature Sensor
- Pack Inlet Pressure Sensor
- Pack Inlet Flow Sensor
- Pack Anti-Icing Pressure Sensor
- Air Cycle Machine or Degraded Pack Performance
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Notice To Operators (NTO): None
Flight Operation Notifications Manual (FONM): None
Quick Links:
None
Troubleshooting Recommendations:
- Perform the following CAIMS troubleshooting:
- Do close out.