Require immediate crew attention. These messages are accompanied by flashing master warning, triple chime attenson with or without voice message or dedicated tone. Require immediate crew awareness and future crew action may be required in the form of alternate system selection or performance limitation. These message are accompanied by flashing master caution and a single chime. Indicate safe or normal system operation which require crew awareness, over and above the dark cockpit philosophy. Indicate minor failures or reduction in systems capability, which require no crew action.

This page includes :

For AOG assistance contact:

CRC Montreal (YUL)
Quick Links

08/29/19

Message Overview:

Fault Message:

[ACSC1-A] LH PACK DISCH OVERHEAT

Fault Code:

2161516ECS

Associated CAS:

L PACK FAIL
(Caution)

Reporting LRU: Air Conditioning System Controller (ACSC) 1
System Description: 21-52-00
Schematic Diagram: 21-52-00 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Wiring Diagram: 21-52-01 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Fault Description:

The Pack Discharge Temperature has been detected in an overheat condition.

Possible Causes:

  • Pack Components/Ducting
  • Air Cycle Machine
  • Pack Inlet Flow Sensor 1 (MT66)
  • Pack Inlet Pressure Sensor 1 (MT65)
  • Pack Discharge Temp Sensor 1 (E27)
  • L Pack Discharge Pressure Sensor (PDPS)
  • Anti-Icing Press Sensor 1 (MT64)
  • Associated Wiring

Troubleshooting Tips:

Advisory Wire/Service Bulletin:

  • AW700-21-0160 - "PACK FAULT" CAS message while CAIMS / OMS is active

Forum Articles/Infoservice/Newsletter: None

Quick Links:

Removal of the Pack Inlet Flow-Sensors AMM 21-51-13-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Pack Inlet Flow-Sensors AMM 21-51-13-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Air Cycle Machines AMM 21-52-09-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Air Cycle Machines AMM 21-52-09-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Condenser/Reheater Units AMM 21-52-21-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Condenser/Reheater Units AMM 21-52-21-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Pack Discharge Temperature-Sensors AMM 21-52-37-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Pack Discharge Temperature-Sensors AMM 21-52-37-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Anti-Icing Pressure Sensors AMM 21-52-41-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Anti-Icing Pressure Sensors AMM 21-52-41-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Removal of the Air-Conditioning System Controllers AMM 21-60-21-000-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Installation of the Air-Conditioning System Controllers AMM 21-60-21-400-801 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Access to System Diagnostics AMM 45-45-00-970-804 [ Global Express ]  [ G5000 ]  [ Global XRS ]
Air Cycle Machine CMM CMM 21-52-09
Wire Repair - Maintenance Practices - ALL SPM 20-12-10 [ Global Express ]  [ G5000 ]  [ Global XRS ]

Troubleshooting Recommendations:

  1. Access CAIMS stored or active faults. If the following fault message is displayed, troubleshoot this message first.

    1. 2162320ECS - LH TEMP CONT VLV CMD /TCV

  2. Make sure the aircraft is located in a hangar and was allowed sufficient time (a few hours) for the PACK temperature to reach ambient air temperature.
  3. Measure and record the ambient air temperature in the aft equipment compartment [Outside Air Temperature (OAT)].
  4. Access CAIMS. Select "SYSTEM DIAGNOSTICS" - ATA 21 - AIR CONDITIONING SYS CON 1A. Select "LRU TEST". Make a selection of "PACK Temp Sensor Data" and record the temperature values for the following sensors:

    Sensor Indicated Temperature Measured Ambient Temperature Tolerance
    PACK INLET ±3 deg from OAT
    PACK (WATER EXTRACTOR) ±3 deg from OAT
    PACK DISCHARGE ±3 deg from OAT
    MIXING MANIFOLD ±3 deg from Cabin Temp

    NOTE: Pack Discharge may show 0 degree. Ok as long as temperature is not dashed.

    1. If there is a difference equal or greater than 3°C (5.4°F), troubleshoot the associated temp sensor.

      1. Pack Inlet temperature sensor
      2. Pack temperature sensor
      3. Pack Discharge temperature sensor
      4. Mix Manifold

    2. If the sensor temperature readings are the same as the measured ambient temperature, continue with next step.

  5. Make sure that the anti-icing pressure sensor vent holes are not covered by the mounting clamps.
  6. Access CAIMS. Select "SYSTEM DIAGNOSTICS" - ATA 21 - AIR CONDITIONING SYS CON 1A. Select "LRU TEST". Make a selection of "PACK Pressure XDCR Data" and record the pressure readings for the following sensors (Do the same with ACSC 2A):

    Sensor Indicated Pressure ACSC 2A Indicated Pressure ACSC 1A Tolerance
    PACK INLET <0.50 PSIA LH to RH
    PACK INLET FLOW (DP) <0.0500 PSID LH to RH
    PACK DISCHARGE <0.0500 PSID LH to RH

    1. If there is a sensor that is out of tolerance, troubleshoot the associated sensor.

      1. Pack Inlet Pressure Sensor
      2. Pack Inlet Flow Sensor
      3. Pack Discharge Pressure Sensor

    2. If the sensor pressure readings are within tolerance, continue with next step.

  7. Swap ACSC 1 with ACSC 2. Is the fault still present?

    1. If YES, continue with next step.
    2. If NO, replace defective ACSC.

  8. Inspect the Pack Discharge Pressure Sensor (PDPS) sense line for damage, the presence of water or other obstruction.
  9. Make sure that the PDPS pressure ports (three 0.052" dia. holes) are not covered by the supporting clamp installation.
  10. Check the following lines and drains for damage or blockage: Air Cycle Machine (ACM) turbine, compressor, water extractor, water nozzle and PDPS Sense Line Drain.
    NOTE: When checking sense lines, ensure there are no cracks in flares of the couplings and that the couplings were properly torqued. It only takes a few drops of water to cause a problem. To purge the lines, they can be blown out with Nitrogen after removing the sensors.
  11. Perform leak check of the Left Pack and ducting.

    1. If leaks are detected, rectify as required.
    2. If no leaks are detected, continue with next step.

  12. Bring the A/C to a location where you will be able to run the APU. In the cockpit, make the following settings:

    1. PACK CONTROL switch to NORM.
    2. XBLEED switch to AUTO.
    3. APU BLEED switch to AUTO.
    4. L PACK and R PACK PBAs to OFF.

  13. Pressurize the air conditioning system with the APU.
  14. Push in the L PACK PBA.
  15. In the Aft equipment compartment, make sure the Air Cycle Machine (ACM) does not make any unusual noises or vibrations. Check for airflow at the ram air outlet to make sure that the ACM rotates correctly.

    1. If the ACM makes unusual noises or vibrations or does not rotate correctly, replace the ACM.
    2. If the check is satisfactory, continue with next step.

  16. Shut down the APU. Remove the left condenser/reheater unit. Attach an electronic torque wrench with an extension and an 11 mm socket to the turbine bolt head. Turn the shaft clockwise for no more than half a revolution while reading the torque value. Make sure the resistant torque value is less than or equal to 3.983 lbf/in (as per CMM 21-52-09.).

    1. If the resistant torque is out of tolerance remove/replace the ACM and send for repair.
    2. If the torque value is good, continue with next step.

  17. Swap Pack Inlet Flow sensors. Is the fault still present?

    1. If YES, continue with next step.
    2. If NO, replace the defective PIFS.

  18. Swap Compressor Discharge Temperature sensors. Is the fault still present?

    1. If YES, continue with next step.
    2. If NO, replace the defective CDTS.

  19. Swap Compressor Discharge Pressure sensors. Is the fault still present?

    1. If YES, continue with next step.
    2. If NO, replace the defective CDPS.

  20. Perform wiring checks of all wires between pack discharge temperature sensor and the ACSC.

    1. If defects are found, repair defective wiring as required.
    2. If no defects are found, continue with next step.

  21. Perform wiring checks of all wires between pack discharge pressure sensor and the ACSC.

    1. If wiring defects are found, repair defective wiring as required and do close out.
    2. If no defects are found, continue with next step.

  22. Perform the following troubleshooting.
  23. Do close out.