06/22/21
Message Overview:
Message Name:
PACK INLET OVERHEAT
| Identifier: | 216OBS006 |
| Effectivity: | All |
| System: | Air Conditioning |
| Associated CAS: | None |
| System Description: | 21-60-00 |
| Schematic Diagram: | 21-60-00 [ Global Express ] [ G5000 ] [ Global XRS ] |
| Wiring Diagram: | None |
Message Description:
An overheat condition is detected at LH/RH pack inlet.
Possible Causes:
- Fan air valve
- Pneumatic temperature thermostat
- Leakage of the pneumatic line between the fan air valve and the pneumatic temperature thermostat
- Pack inlet flow sensor
- Leakage on the cold air side (fan air) of the pre-cooler exchanger.
- Blockage in the fan air valve ducts.
- Pack inlet temperature sensor
Troubleshooting Tips:
Advisory Wire/Service Bulletin: None
Forum Articles/Infoservice/Newsletter: None
Notice To Operators (NTO): None
Flight Operation Notifications Manual (FONM): None
Troubleshooting Recommendations:
- Perform the following CAIMS troubleshooting:
- Do close out.